Specifications

Features in 291-04 140
Version 291-18
C613-10488-00 REV Q
CR00009087 Core, Utility 4 The following issues occurred with the commands show debug active and
disable debug active:
The command did not adequately warn users if an invalid module number had
been entered into the active parameter.
This issue has been resolved. The router or switch now displays an error unless
the value is between 1 and 142.
The CLI “?” help description for the active parameter listed an incorrect
number range and also listed modules that cannot be manipulated through
this command.
This issue has been resolved. The “?” help description is now correct.
YYYYYYYYYY
CR00011695 QoS 4 The “?” help description for switch commands that accept a value in bytes (or
similar units such as kbytes or bytes/s) incorrectly indicated that the units were
bps. The commands this issue applied to depend on the switch model, but
include commands such as:
create qos trafficclass=value maxburst=?
create qos policy=value dtcmaxburst=?
set qos red=value start1=?
set swi port=value bcl=?
set swi dlfl=?
This issue has been resolved. The “?” help description now displays the correct
units.
YYYYYYY
CR00012602 MSTP 4 If the command set mstp cist port=value was entered with no other
parameters, the resulting error message (“One or more parameters may be
missing”) was displayed as an INFO message.
This issue has been resolved. The message now displays as an ERROR message.
YYYYYY–
CR00013045 SNMP, Core,
TTY
4 The MIB object hrSystemNumUsers displayed the number of login users since the
router or switch started up, instead of the number of currently-active login users.
This issue has been resolved.
YYYYYYYYYY
CR Module Level Description
AR400
AR7x5
AR7x0S
Rapier i
AT-8800
AT-8600
AT-8700XL
x900-48
AT- 9900
AT-9800