Specifications

Features in 291-04 139
Version 291-18
C613-10488-00 REV Q
Level 4
CR00015666 IP Gateway 3 Subnet broadcast packets would not be routed correctly when the interface to
which the subnet broadcast was destinated was an interface on the device, but
its link status was down. Even though an alternate route to the destination
existed, the device would send the packets incorrectly.
This issue has been resolved. When a subnet broadcast is received, it will be
correctly forwarded to an alternate route even if the destination interface is
down.
YYYYYYYYYY
CR00015798
CR00016058
Switch 3 If the switch received a packet on a port and therefore started using MAC-based
authentication to authenticate the port, and then received another packet during
the authentication process, then occasionally the switch dropped the second
packet.
This issue has been resolved.
YYYYYYYYY–
CR00015915 Ethernet 3 The AR415S router processed some IP multicast packets incorrectly on its eth0
interface.
This issue has been resolved.
Y–––––––––
CR Module Level Description
AR400
AR7x5
AR7x0S
Rapier i
AT-8800
AT-8600
AT-8700XL
x900-48
AT- 9900
AT-9800
CR00004677 Core 4 When the router or switch rebooted, its internal clock lost approximately
1 second.
This issue has been resolved. The time loss on reboot has been reduced.
YYYYY–YYYY
CR Module Level Description
AR400
AR7x5
AR7x0S
Rapier i
AT-8800
AT-8600
AT-8700XL
x900-48
AT- 9900
AT-9800