Installation guide

BlackDiamond 8800 Series Switches Hardware Installation Guide
73
Selecting Cable
This section provides information that is helpful when you must select the cables to be used with the
BlackDiamond 8800 series switch.
Cable Distances
Table 17 shows cable media types and maximum distances that support reliable transmission in
accordance with international standards, except where noted.
RJ-45 Connector Jackets
Use RJ-45 cable with connector jackets that are flush with the connector or that have connectors with a
no-snag feature.
Using cable with jackets that are wider than the connectors can cause:
Connectors that are not properly aligned with the port.
Crowded cable installation, which can cause connectors to pop out of the port.
Figure 40 shows examples of connector jacket types that are not recommended, as well as those that are
recommended.
Table 17: Media Types and Maximum Distances
Standard Media Type
Mhz•Km
Rating
Maximum Distance
(Meters)
1000BASE-SX
(850 nm optical window)
50/125 μm multimode fiber
50/125 μm multimode fiber
62.5/125 μm multimode fiber
62.5/125 μm multimode fiber
400
500
160
200
500
550
220
275
1000BASE-LX
(1300 nm optical window)
50/125 μm multimode fiber
50/125 μm multimode fiber
62.5/125 μm multimode fiber
10/125 μm single-mode fiber
10/125 μm single-mode fiber
1
1.Proprietary to Extreme Networks. Connections between two Extreme Networks 1000BASE-LX interfaces that use
10/125 μm single-mode fiber can use a maximum distance of 10,000 meters.
400
500
500
550
550
550
5,000
10,000
1000BASE-LX70
(1550 nm optical window)
10/125 μm single-mode fiber 70,000
1000BASE-T
100BASE-TX
10BASE-T
Category 5 and higher UTP cable
Category 5 and higher UTP cable
Category 3 and higher UTP cable
100
100
100