Install guide

Software Version 2.8.1 53
Software Version 2.8.1
C613-10477-00 REV B
Command Reference Updates
This section describes the changed portions of modified commands and output
screens. For modified commands and output, the new parameters, options,
and fields are shown in bold.
set asyn
Syntax SET ASYn[=asyn-number] [ATtention={Break|alphabetical
control char|^[|None}]
[CDcontrol={Connect|Ignore|Online}]
[DAtabits={5|6|7|8}]
[DEFaultservice={ON|OFf|YES|NO|True|False}]
[DTrcontrol={Connect|OFf|ON}]
[Echo={ON|OFF|YES|NO|True|False}] [ENable={BREAK|NONE}]
[Flow={Character|HArdware|None}] [History=0..99]
[IDLEtimeout={10..4294967294|OFF|0}]
[INFlow={Character|HAreware|None}]
[IPaddress={ipadd|NONe}] [IPXnetwork=network]
[LOGin={ON|OFf|YES|NO|True|False}]
[MAXoqlen=0..4294967295] [MTu=40..1500] [NAme=name]
[OUTFlow={Character|HArdware|None}] [PAGe={0..99|OFF}]
[PARity={Even|Mark|None|Odd|SPace}]
[PRompt={prompt|DEFault|OFf}]
[SECure={ON|OFf|YES|NO|True|False}]
[SERvice={service-name|None}]
[SPeed={AUTO|75|110|134.5|150|300|600|1200|1800|2000|24
00|4800|9600|14400|14.4K|19200|19.2K|28800|28.8K|38400|
38.4K|57600|57.6K|115200|115.2K}] [STopbits={1|2}]
[TENtimervalue=20..100] [TIMeout=1..65535]
[TYpe={Dumb|VT100}]
Description The new tentimervalue parameter sets the length of the ten timer, in
milliseconds. Reducing the length of the ten timer increases the port’s
responsiveness (see “Making Asynchronous Ports Respond More Quickly on
page 52). Unless you are logged in via the port you want to change, also specify
the asynchronous port number. The default tentimervalue is 100.
show asyn
Syntax SHow ASYn[=port-number|ALL]
[{COUnters[={Diagnostic|INTerface|Rs232}]|History|
Summary}]
Description When you specify asyn=port-number or asyn=all, the output of this command
now includes a new field (Figure 13, Table 12).