Specifications
Hardware Reference 33
C613-03064-00 REV E
Figure 11: EPROM locations.
7. Insert the new boot EPROMs.
Insert the new boot EPROMs one at a time, using as a reference the location
number printed on the CPU board (e.g., “0” and “1”) and Figure 11 on
page 33. Check that the boot EPROMs are firmly seated.
Install the boot EPROMs the correct way up! Failure to do so will almost certainly
destroy them. The ‘top’ end of the EPROM has a notch. This should be positioned so that
the notched end of the EPROM is orientated as shown in Figure 11 on page 33.
8. Replace the switch’s lid and power cord.
Replace the lid and secure it with the 12 posidrive screws. Connect the
power cord and (if disconnected in step 4) the RPS.
9. Check that the switch is operating correctly.
Check that the switch boots up correctly. Connect the switch’s RS-232
Terminal Port to a terminal (see page 20 for information on connection
cables) and check the start-up messages. See “Switch Start-up” on page 12
for a list of start-up messages. Verify that the new software release is
installed by typing the command:
SHOW INSTALL
which will produce a display like that shown in Figure 12 on page 34. The
boot EPROM software release number is shown in the “Default” field.
Check that it is correct.
Boot EPROMs
Fan
8700eprom