User guide

Provisioning the iMG/RG LAN Flow Control
889
AlliedView NMS Administration Guide
FIGURE 7-222 Controlling power Management for Voice Lines on Service Management Form
7.15.5 Voice Ports State
Also on the Advanced Line Params for voice service is a read-only field that shows the state of the port:
Busy - The line is being used. Note that during this state, it cannot be powered down by the Power Management feature
if there is a loss of power.
Idle - Line is ready to place and receive calls.
Out of Service - Line has been disabled.
Powered Down - The Power Management Feature has activated and on the voice port the Disable on Power Failure was
set to Enabled.
This status field can be seen on Figure 7-222.
7.16 LAN Flow Control
On ingress traffic, when internal ingress queues are almost full or the rate limit is exceeded, the iMG/RG sends a PAUSE
frame for all traffic on the port. (The downstream device must ensure traffic is not lost.)
The feature is included in the Advanced Port Attributes panel for the RG General Profile and the Service Management Form.
Refer to the following figures.