User guide

Provisioning the iMG/RG Creating RG Profiles with Field Descriptions
675
AlliedView NMS Administration Guide
TABLE 7-7 Create RG General Port Profile Form - Mgmt InfoTab
Attribute Value
Profile Name A descriptive name that should match the service/function provided
The prefix of profile name should start with a short but meaningful name that
indicates the routing function and the Access Island and the service potential of the
general profile, with the number of ports. Refer to 7.4.1. This is used for scoping.
SPSI-AI01-1I_2V_3T (VoIP Telephone, 1 Internet, 2 Video, 3TLS)
Note: Profile names can only be up to 20 characters. To include all services, the
administrator may need to delete an underscore. This is OK as long as the
prefix works for scoping.
Profile Scoping When used in conjunction with the Triple-Play form, controls the profiles available
after selecting the device.port, or controls the device.port available after selecting the
Profile.
iMG/RG Bootstrap VLAN Id The default VLAN on the RG that is used when sending the original Discover
Message. This is “out of the box” (factory configuration). This is used only through
bootstrap 1 usually
Persist Checkbox Used to retain the bootstrap VLAN at the end of triple play provisioning to aid in the
replacement of faulty CPE. It can also put the bootstrap VLAN on the port when the
profile (with Persist checked) is applied to the port from the View/Modify screen or
deployed from the deploy profile tool.
iMG/RG Mgmt VLAN Id The VLAN used for subsequent downloads once communication is established with
the AlliedView NMS. It is derived from the im.conf file.
Include Service VLANs in
Profile
Controls which network model is to be used.
True - Access Island model is being used, and service VLAN fields are activated.
False - Open Access model is being used, and service VLAN fields are de-activated.
Internet VLAN The VLAN used for internet type service
Video VLAN The VLAN used for video type service
Voice VLAN The VLAN used for voice type service
CES VLAN The VLAN used for CES type service
iMG/RG Additional VLAN
IDs
Shows VLAN IDs for custom VLANs. Use the Add/Remove button to open the
Additional VLANs panel. Note that port service must be set to “None” to add an
additional VLAN to the iMG. Refer to 7.9.8.
System Power Management Whether this feature is Enabled or Disabled. Refer to 7.15.
Loop Detection Only supported on 10M-half duplex interfaces, it is primarily intended for Ethernet
links that have Baluns connected to them, which if not terminated correctly can
reflect packets back. Setting to Enabled prevent this.
SNTP Server The IP address for the SNTP server, used to derive the correct time and time
settings. (Default is None.)
Daylight Saving Enables or Disables the Daylight Savings Feature for the iMG/RG. Note that this is
only for 3-7 devices. This is also available on the Services Management Window.
Time Zone Time Zone for the iMG, for example EST for Eastern Standard Time.
Note: For TR-069 CPEs, this is determined by the SNTP server setting, and so
SNTP Server must be filled in first. If no SNTP server is provisioned, the
iMGs default to “clock.fmt.he.net”.
Limited User Login User ID of user with limited capabilities