User guide

Controlling and Provisioning Network Devices Port Management (iMAP Devices)
307
AlliedView NMS Administration Guide
5.6.20.6 Port Thresholds Tab
This form allows the user to modify the threshold values for the DS1/E1 and PPP statisitcs.When a new value is entered in
the New Value field, the Modify button is enabled.
Note: In most cases, these DS1/E1 values are not modified because they are part of the DS1/E1 port profile; if the user does
change a value, the port is now out of sync with its associated profile, and “* “will appear next to the Profile name on the
DS1/E1 Port tab form (as well as the Port Inventory table). In the dual endpoint configuration, the “*” will appear next to the
specific port where the values were changed from the Profile. To Resync the port, the user must re-apply the profile on the
DS1/E1 tab form, which puts the values back to what they are in the Profile.
Display The attribute that controls the display:
- Absolute Values
- Rate Per Second
- Million Per Second
Polling Interval: The Current Polling Interval in seconds
New Interval: Sets a new interval for polling. This is set with the Reset Polling Interval button.
Add Historical Data from
NMS:
Adds the data collected previously from NMS Performance Management
Add Historical Data from
Device:
Adds the data collected previously from the device.
TABLE 5-50 NTE DS1 Port Management - Stats Graph Tab
Field/Button Description