Installation guide
AT-S25 Management Software Release Notes
613-50514-00 Rev A 11 Allied Telesyn, Inc.
New AT-S25 Version 2.0.2
Resolved Issues
❑ The gigabit appliqués on the 8324 cannot pass 64-byte frames at wire rate. We are only
seeing 60-80% throughput. Reference Customer #98583 (Bugzilla # 512).
❑ STP is not working between two AT-8324's when there is a redundant connection
between two A-15 appliqués. Both connections remain in the forwarding state as the
root. Reference Customer #100170 (Bugzilla # 522).
❑ The A-15 appliqué cannot switch between manual and Auto-Negotiation modes. The
port is always set in manual mode, which makes it impossible to send traffic to a partner
that is Auto-Negotiating. Reference Customer # 100573 (Bugzilla # 513).
❑ The Port Priority feature is not working correctly. Traffic on the low-priority queues is
handled the same as the traffic on the high-priority queues. Reference Customer
#101225 (Bugzilla # 517).
❑ When trunked ports are tagged, traffic is sent through trunk-out without a tag.
Example:
Switch A - VLAN 2 UNTAGGED 24
VLAN 2 TAGGED 1-4
Trunk Group 1 = ports 1-4
Switch B - VLAN 2 UNTAGGED 24
VLAN 2 TAGGED 1-4
Trunk Group 1 = ports 1-4
Host A on switch A is connected to port 24.
Host B on switch B is connected to port 24.
Traffic sent over tagged trunk is not tagged for VLAN 2 as it should be. Reference
Customer # 102111 (Bugzilla # 502).
❑ A problem will occur when a customer repeatedly opens and closes the Telnet session
without waiting for the command execution to complete. This problem was found
when a script was being executed and the Telnet session was aborted. The switch was
still displaying information while the Telnet session being aborted.
❑ Problem:
The IGMP timer becomes inaccurate when it is set for a longer time. For example, a 60-
second timer setting actually flushes at around 90 seconds, and a-120 second timer
flushes at around 210 seconds. Reference Customer #102597 (Bugzilla # 561).