Layer 2 Ethernet Switch Allied Telesis AT-8000S Installation Guide AT-8000S Series Stackable Gigabit Ethernet Switches 613-001106 Rev C
Copyright 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
Table of Contents Table of Contents Preface.................................................................................................................................... 6 How This Guide is Organized .......................................................................................................... 6 Document Conventions ................................................................................................................... 6 Product Description.....................................
Allied Telesis AT-8000S Switch Switch Installation Guide Stacking ................................................................................................................................ 30 Understanding the Stack Topology ............................................................................................... 30 Stacking Chain Topology .............................................................................................................. 31 Stacking Members and Unit ID ..............
Table of Contents Page 5
Allied Telesis AT-8000S Switch Installation Guide Preface This guide contains the hardware installation instructions for the AT-8000S/16, AT-8000S/24, AT-8000S/24POE, AT-8000S/48 and AT-8000S/48POE Fast Ethernet Switches. How This Guide is Organized This manual contains the following chapters: • Chapter 1 Product Description describes the features and components of the switches. • Chapter 2 Installation describes the installation instructions for the switches.
Contacting Allied Telesis Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base from the following web site: www.alliedtelesis.com/kb. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
Allied Telesis AT-8000SSwitch Switch Installation Guide Chapter 1. Product Description The new AT-8000S series combines the best of the previous L2 series; stackability and affordability. The new AT-8000S series is an entry level managed switch for the SMB, Small Office/Field Office offering managed desktop connectivity. The fiber uplink provides connectivity between workgroups over a larger distances.
Product Description Features The AT-8000S/16, AT-8000S/24, AT-8000S/24POE, AT-8000S/48 and AT-8000S/48POE features include the following: • • • • • • • • • • • • • • • • • • • • • • • • • • • Wirespeed switching traffic across all ports Auto MDI/MDIX enabled 802.1d, 1w, 1s priority tags supported Broadcast storm control IEEE 802.1Q tagged VLANs supported GARP/GVRP supported Port/MAC based VLANs supported 802.3ad link aggregation Static and Dynamic (LACP) supported IEEE 802.
Allied Telesis AT-8000SSwitch Switch Installation Guide AT-8000S/16 Front Panel The following figure illustrates the AT-8000S/16 front panel. Figure 1: AT-8000S/16 Front Panel The AT-8000S/16 front panel is configured as follows: • • • • • • 16 10/100Mbps Ports — RJ-45 ports designated as 10/100Base-T. The RJ-45 ports are designated as ports Ports 1 - 16. 1 10/100/1000Base-T Copper Port — There is one copper 10/100/100Base-T port designated on the switch as port 17R.
Product Description AT-8000S/24 Front Panel The following figure illustrates the AT-8000S/24 front panel. Figure 3: AT-8000S/24 Front Panel The AT-8000S/24 front panel is configured as follows: • • • • • • 24 10/100Mbps Ports — RJ-45 ports designated as 10/100Base-T. The RJ-45 ports are designated as ports Ports 1 - 24. 2 10/100/1000Base-T Copper Ports — There are two copper 10/100/100Base-T ports designated on the switch as ports 25R and 26R.
Allied Telesis AT-8000SSwitch Switch Installation Guide AT-8000S/24POE Front Panel The following figure illustrates the AT-8000S/24POE front panel. Figure 5: AT-8000S/24POE Front Panel The AT-8000S/24POE front panel is configured as follows: • • • • • 24 10/100Mbps Ports — RJ-45 ports designated as 10/100Base-T. The RJ-45 ports are designated as ports Ports 1 - 24. 2 10/100/1000Base-T Copper Ports — There are two copper 10/100/100Base-T ports designated on the switch as ports 25R and 26R.
Product Description AT-8000S/48 Front Panel The following figure illustrates the AT-8000S/48 front panel. Figure 7: AT-8000S/48 Front Panel The AT-8000S/48 device front panel is configured as follows: • • • • 48 10/100Mbps Ports — RJ-45 ports designated as 10/100Base-T. The RJ-45 ports are designated as ports Ports 1 - 48. 2 10/100/1000Base-T Copper Ports — There are two copper 10/100/100Base-T ports designated on the switch as ports 49R and 50R.
Allied Telesis AT-8000SSwitch Switch Installation Guide AT-8000S/48POE Front Panel The following figure illustrates the AT-8000S/48POE front panel. Figure 9: AT-8000S/48POE Front Panel The AT-8000S/48 device front panel is configured as follows: • • • 48 10/100Mbps Ports — RJ-45 ports designated as 10/100Base-T. The RJ-45 ports are designated as ports Ports 1 - 48. 2 10/100/1000Base-T Copper Ports — There are two copper 10/100/100Base-T ports designated on the switch as ports 49R and 50R.
Product Description 10/100Base-T Fast Ethernet Ports Ports Description 10/100Base-T Fast Ethernet Ports The 10/100Base-T Fast Ethernet ports are RJ-45. The 10/100 Mbps port supports half- and full-duplex mode. 10/100/1000Base-T Uplink Ethernet Ports The 24/48 port devices contains two 10/100/100Base-T Gigabit ports, and the 16 port device contains one 10/100/100Base-T port. The RJ-45 1000 Mbps port supports 1000 mbps in full-duplex mode and 10/100 mbps half- and full-duplex mode.
Allied Telesis AT-8000SSwitch Switch Installation Guide Mode LEDs Selecting a particular mode determines what information is displayed on the port LED. For example, if the mode selected is "COL", then the LED on each port indicates the collision status of that port. The following figure illustrates the mode LEDs.
Product Description Port LEDs The stacking LED indications are described in the following table: Table 2: Stacking LED Indications LED D e s c r i pt i on LE D I n di c a t i on De s c r i pt i on All LEDs off The device is operating as a standalone switch. Green The device is master-enabled, and is either the master or backup of the stack, which is determined by the master election algorithm.
Allied Telesis AT-8000SSwitch Switch Installation Guide The RJ-45 ports have two LEDs, one for Link and one for activity (Mode status for non PoE and Load status for PoE). The LED indications are described in the following table: Table 3: 10/100Base-T Fast Ethernet RJ-45 Port LED Indications Por t Des criptio n L ED In dica tio n D escr ip tio n Left LED - Link Green A 100-Mbps link is established on the port. Off No link is established on the link.
Product Description Port LEDs The 1000 Base-T/Combo Ethernet RJ-45 ports have two LEDs, one for speed and one for Link and activity. The LED indications are described in the following table: Table 4: Combo Port LED Indications P or t D e s c r i pt i o n LE D I nd ic a t i on D e s c r i p t io n Copper Port Left LED - Speed Green A 1000-Mbps link is established on the port. Amber A 100-Mbps link is established on the port. Off A 10-Mbps Link is established on the port / No link established.
Allied Telesis AT-8000SSwitch Switch Installation Guide 24/48 Port Device System LEDs There are two system LEDs, the Power and Diagnostics LEDs. The following figure illustrates the Power and Diagnostics LEDs. Figure 16: SFP Port LEDs Power LED The PWR LED on the front panel of the device indicates the power supply status.
Product Description Stacking Ports LEDs Stacking Ports LEDs The following figure illustrates the Stacking port LEDs. Figure 17: Stacking Port LEDs The RJ-45 ports have two LEDs, one is for link and one is for activity. The Stacking LEDs indications are described in the following table: Table 8: Stacking Ports LEDs Indications Por t D escr ip tio n L ED In dica tio n D escr ip tio n Left LED - Link Green A link is established on the port. Off No link is established on the port.
Allied Telesis AT-8000S Switch Switch Installation Guide Chapter 2.
Installation Preparing for Installation Warning Do not work on equipment or cables during periods of lightning activity. E2 Warning Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. E3 Warnings • • Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth grounded socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. E4 Pluggable Equipment.
Allied Telesis AT-8000S Switch Switch Installation Guide Caution Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. E36 Warning Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuits (e.g., use of power strips).
Installation Installing the Device Package Contents While unpacking the device, ensure that the following items are included: • One AT- 8000S/xx series unit • Rubber Feet for desktop installation • Rack-mount kit hardware accessories • An AC power cable • Stacking cable (Yellow color) • Console RS-232 cable with DB-9 connector • Installation guide on CD • Warranty and registration card Unpacking Essentials Note Before unpacking the device, inspect the package and report any evidence of damage immediately.
Allied Telesis AT-8000S Switch Switch Installation Guide Figure 18: Installing Rubber Feet 2. 3. Set device down on a flat surface, while leaving 2 inches on each side and 5 inches at the back. Ensure that the device has proper ventilation by allowing adequate space for ventilation between the device and the objects around the device. Rack Installation The device can be mounted in an EIA standard-sized, 19-inch rack, which can be placed in a wiring closet with other equipment.
Installation Connecting the Device Figure 19: Attaching the Mounting Brackets 4. 5. 6. 7. Insert the supplied screws into the rack mounting holes and tighten with a screwdriver. Repeat the process for the rack-mounting bracket on the other side of the device. Insert the device into the 19-inch rack and secure the unit to the rack with the rack screws (not provided by the ATI supplier). When securing, fasten the lower pair of screws before the upper pair of screws.
Allied Telesis AT-8000S Switch Switch Installation Guide To connect a terminal to the device Console port, perform the following: 1. Connect a cable to the terminal running VT100 terminal emulation software. 2. Ensure that the terminal emulation software is set as follows: a) Select the appropriate port to connect to the device. b) Set the data rate to 115,200 baud. c) Set the data format to 8 data bits, 1 stop bit, and no parity. d) Set flow control to none.
Installation Connecting the Device Page 29
Allied Telesis AT-8000SSwitch Installation Guide Chapter 3. Stacking Stacking provides multiple switch management through a single point as if all stack members are a single unit. All stack members are accessed via a single IP address through which the stack is managed. The stack can be managed from the following: • • Embedded Web-based Interface Command Line Interface (CLI) Devices support stacking up to six units per stack, or can operate as stand-alone units.
Stacking Stacking Chain Topology Figure 20: Stacking Ring Topology Most difficulties incurred in Ring topologies occur when a device in the ring becomes non-functional, or a link is severed. In a stack, the system automatically switches to a Stacking Failover topology without any system downtime. An SNMP message is automatically generated, but no stack management action is required. However, the stacking link or stacking member must be repaired to ensure the stacking integrity.
Allied Telesis AT-8000SSwitch Installation Guide Configuring Stacking Configuring stacking is performed during the bootup process. To configure a device as part of a stack, the bootup process must be interrupted straight after the Power On Self Test (POST). To configure the device for stacking, perform the following: 1. 2. 3. 4. Ensure that the device console is connected to a VT100 terminal device or VT100 terminal emulator. Deactivate the AC power receptacle. Connect the device to the AC receptacle.
Stacking Configuring Stacking The Startup Menu is displayed and contains the following configuration functions: Startup Menu [1] Download Software [2] Erase Flash File [3] Password Recovery Procedure [4] Enter Diagnostic Mode [5] Set Terminal Baud-Rate [6] Stack menu [7] Back Enter your choice or press 'ESC' to exit: 6. From the Startup Menu, press “6”.
Allied Telesis AT-8000SSwitch Installation Guide Chapter 4.
Initial Configuration Configuration Note 100.1.1.254 is the IP address of the default gateway that is used to reach the management network 101.101.0.0. To check the configuration, enter the command “show ip interface” as illustrated in the following example. Console# show ip interface Gateway IP Address Activity Status Type ----------------------------- ---------------- --------- 100.1.1.254 active static IP Address I/F Type ----------------------------- ---------------- --------- 100.1.1.
Allied Telesis AT-8000S Switch Installation Guide Chapter 5. Troubleshooting This chapter contains information on how to troubleshoot the switch in the event that a problem occurs. Note If you are still unable to resolve the problem after following the instructions in this chapter, contact ATI Technical Support for assistance. Device not operating correctly Check the PWR LED on the front of the switch.
Troubleshooting Page 37
Allied Telesis AT-8000S Switch Installation Guide Appendix A. Technical Specifications Physical Specifications The different devices have the following physical specifications: • AT-8000S/16 + 1G — 330 x 230.5 x 43.2 mm (W x D x H) • AT-8000S/24 + 2G — 440 x 257 x 43.2 mm (W x D x H) • AT-8000S/24 + 2G w/ POE — 440 x 257 x 43.2 mm (W x D x H) • AT-8000S/48 + 2G — 440 x 257 x 43.2 mm (W x D x H) • AT-8000S/48 + 2G w/ POE — 440 x 387 x 43.2 mm (W x D x H) Weight • • • AT-8000S/16 —1.95kg AT-8000S/24 — 3.
Technical Specifications Compliance Standards The devices conform to the following compliance standards: • • • • The Environmental standard, per ATI QLT 1220 RoHS compliant The EN50082-1 immunity standard The following safety standards: – – – – UL1950 – – – – FCC Class A CSA22.2 no.
Allied Telesis AT-8000S Switch Installation Guide Table 9: RJ-45 Pin Connections for 10/100/1000 Base-T Pin U se 3 TxRx 2+ 4 TxRx 3+ 5 TxRx 3- 6 TxRx 2- 7 TxRx 4+ 8 TxRx 4- Page 40
Technical Specifications Page 41
Allied Telesis AT-8000SSwitch Installation Guide Appendix B. Safety Statements Important: This appendix contains multiple-language translations for the safety statements in this guide. Wichtig: Dieser Anhang enthält Übersetzungen der in diesem Handbuch enthaltenen Sicherheitshinweise in mehreren Sprachen. Importante: Este apéndice contiene traducciones en múltiples idiomas de los mensajes de seguridad incluidos en esta guía.
Safety Statements Electrical Safety Notices Warning 5. Power cord is used as a disconnection device. To de-energize equipment, disconnect the power cord. Warning 6. Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth grounded socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts. Warning 7. Pluggable Equipment.
Allied Telesis AT-8000SSwitch Installation Guide Warning 13. Do not strip more than the recommended amount of wire. Stripping more than the recommended amount can create a safety hazard by leaving exposed wire on the terminal block after installation. Warning 14. When installing this equipment, always ensure that the frame ground connection is installed first and disconnected last. Warning 15. Check to see if there are any exposed copper strands coming from the installed wire.
Safety Statements Electrical Safety Notices Warning 23. The power source for the gateway unit should be located near the unit and should be easily accessible. Caution 24. To allow proper cooling of the gateway device, make sure that the air flow around the unit and through its heatsink cooling fins on the rear is not restricted. Caution 25.
Allied Telesis AT-8000SSwitch Installation Guide Warning 30. Remove all metal jewelry, such as rings and watches, before installing or removing a line card from a powered-on chassis. Warning 31. Use dedicated power circuits or power conditioners to supply reliable electrical power to the device. Warning 32. The chassis may be heavy and awkward to lift. Allied Telesis recommends that you get assistance when mounting the chassis in an equipment rack. Warning 33.
Safety Statements Telecommunications Compliance Notices Caution 39. If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra). Caution 40.
Allied Telesis AT-8000S Switch Installation Guide Index Numerics 10/100Base-T 15 1000Base-T 15 A AT-8000S/16 10 AT-8000S/24 11 AT-8000S/24POE 12 AT-8000S/48 13 AT-8000S/48POE 14 Autoboot 32 C Command Line Interface 8 Compliance Standards 39 Configuration Overview 34 Configuring Stacking 32 D Data collisions 16 DB-9 8 Diagnostic LED 20 E Embedded Web Server 8 Environmental Specifications 38 F Fast Ethernet 15 Full Duplex mode 16 H Half Duplex mode 16 I Initial Configuration 34 L Light Emitting Diodes 15 M M