You may enter a new name, up to 20 characters in length, or press RETURN to 
keep the existing symbolic name. To delete an existing name, enter one or 
more space characters (blanks) and then press RETURN.
Ethernet Parameters
The AT-4016 as well as the AT-TS95TR, offer the choice of store-and-forward 
(the default) or cut-through switching strategies. In store-and-forward, the 
AT-4016 stores the entire packet before it is forwarded. 
Error packets which do not have a valid Ethernet length will be discarded 
using store-and-forward but not with cut-through. Due to this software 
implementation, there is a minimal latency difference between cut-through 
and store-and-forward. The preferred method is store-and-forward. 
Choose the System Administration submenu again and enter the letter E 
for Ethernet parameters to access the following submenu:
 NOTE
All changes to Ethernet parameters require a system reset to be activated.
The Ethernet parameters screen shows the current choices for 
forwarding and for LED modes of operation. At the bottom you see a list of 
menu options. Each currently configured choice is highlighted with an 
arrowhead (“>”).
Enter the letter 
S or the letters CU if you wish to change the forwarding 
mode. Enter the letter T or the letters CO if you wish to change the LED 
mode.