Installation guide
Network Adapter Card Installation Guide - Book II
77
Note
Sense-mode will fail if your link partner is configured to half-duplex
with no auto-negotiation enabled. AutoNegotiation_? and
DuplexCapabilities_? have to be set manually in this case.
Note
Sense-mode is not possible with 1000Base-T (copper) adapters. If
you select Sense, it will be mapped to ON automatically.
DuplexCapabilities_?_InstX
Type: string
Default value: Both
Valid values: Half
Full
Both
Both: Port can connect with full-duplex and half-duplex.
Full: Port connects with full-duplex.
Half: Port connects with half-duplex.
This parameter is ignored if 'AutoNegotiation' is set to Sense.
If auto-negotiation is set to ON, all three values are possible. If it is set to
OFF, only Full or Half are allowed. This parameter is useful if your link
partner does not support all possible combinations.
FlowControl_?_InstX
Type: string
Default value: SymOrRem
Valid values: Sym
SymOrRem
LocSend
None
This parameter can be used to set the flow control capabilities the port
reports during auto-negotiation.