Owner manual

AlliedView™-EMS 3.11 QoS Manager User’s Guide Page 125 of 146
6.9 Rapier
Topics:
Classifiers
Flow Groups
Traffic Classes
Policies
Ports
Scheduling
Quick Setup
Notes
6.9.1 Classifiers
6.9.1.1 QoS Information Window
Column Name Description
Classifier ID Lists the Rule ID of packet-matching rules available
6.8.1.2 Add/Modify Classifier
Property Name Description Valid Values
Rule ID
(cannot be
modified)
Uniquely identifies the packet-
matching rule
Range: 1-9999
Egress Port Specifies the egress port on the
switch to match for each frame.
This can be set by selecting any of
the following values:
1-N (where N is the number
of ports available on the
device)
This value can also be set to
"any".
Ingress Port Specifies the ingress port on the
switch to match for each frame.
This can be set by selecting any of
the following values:
1-N (where N is the number
of ports available on the
device)
This value can also be set to
"any".
Ingress Interface Specifies the interface through This can be set by selecting the