User Manual

6.5.3.1 Add/Modify Traffic Class
Property Name Description Valid Values
Traffic Class ID
(cannot be
modified)
Specifies the unique identifier
for this Traffic Class.
Range: 0-511
Description Specifies a brief description of
the Traffic Class.
To set this value, enter an
alphanumeric string from 1-15
characters.
Exceed Action Specifies the action to take if
the traffic classes
maxbandwidth is exceeded.
drop
remark
Exceed Remark
Value
Specifies the DSCP
replacement value for traffic
that exceeds the
maxbandwidth.
Range: 0-63
Mark Value Specifies a replacement value
to write into the DSCP (TOS)
field for all packets.
Range: 0-63
Maximum
Bandwidth
Specifies the maximum
bandwidth available to the
traffic class.
Range: none, 0-1016
Burst Size Specifies the size of a token
bucket for the Traffic Class.
Range: none, 4-512
Priority Specifies the priority value in
the IEEE Standard 802.1p tag
control field that traffic
belonging to this traffic class is
assigned.
Range: 0-7
Remark
Priority
Specifies whether the value of
the priority parameter is used
to set the egress queue
selection for a frame and also
to replace the 802.1p priority
value in the frame, or just to
select the egress queue for the
frame.
yes
no
Type of Service Specifies the replacement value
to write in the Type of Service
field of IPv4 packets.
Range: none, 0-7
Move TOS to
Priority
Specifies whether or not the
value in the 802.1p priority field
will be replaced with the value
in the ToS priority field on IPv4
packets.
yes
no
Move Priority Specifies whether or not the yes
AlliedView™-EMS 3.10 QoS Manager User’s Guide Page 58 of 128