User Manual
Property Name Description Valid Values
Priority This parameter specifies the
priority that traffic belonging to
this Flow Group has.
Range: none, 0-7
Remark
Priority
Specifies whether the value of
the priority parameter is used
to set the egress queue
selection for a frame and also
to replace the 802.1p priority
value in the frame, or just to
select the egress queue for the
frame.
• yes
• no
Classifier List Specifies a list of the Classifiers
currently assigned to this Flow
Group.
Select from a list of available
classifier IDs.
6.8.3 Traffic Classeses
6.8.3.1 QoS Information Window
Column Name Description
Traffic Class ID Lists the ID of Traffic Classes available
Description A brief description of the Traffic Class
Flow Groups List of the Flow Groups associated with this
Traffic Class
6.8.3.1 Add/Modify Traffic Class
Property Name Description Valid Values
Traffic Class ID
(cannot be
modified)
Specifies the unique identifier
for this Traffic Class.
Range: 0-511
Description Specifies a brief description of
the Traffic Class.
To set this value, enter an
alphanumeric string from 1-15
characters.
Exceed Action Specifies the action to take if
the traffic classes
maxbandwidth is exceeded.
• drop
• remark
Exceed Remark
Value
Specifies the DSCP
replacement value for traffic
that exceeds the
maxbandwidth.
Range: 0-63
Mark Value Specifies a replacement value
to write into the DSCP (TOS)
field for all packets.
Range: none, 0-63
Maximum Specifies the maximum This can be set by entering a
AlliedView™-EMS 3.10 QoS Manager User’s Guide Page 114 of 128