AT-2716POE Fast Ethernet Fiber & PoE Adapter TX ATI TF X 2317 Installation and Users Guide 613-001265 Rev.
Copyright © 2011 Allied Telesis, Inc. All rights reserved. No part of this publication may be reproduced without prior written permission from Allied Telesis, Inc. Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis, Incorporated. All other product names, company names, logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners. Allied Telesis, Inc.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Electrical Safety and Emissions Standards This product meets the following standards: Federal Communications Commission Interference Statement Declaration of Conformity Manufacturer Name: Allied Telesis, Inc. Declares that the product: Fast Ethernet Adapters Model Numbers: AT-2716POE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide RFI Emissions FCC Class A Immunity EN55024 Electrical Safety EN60950-1 (TUV), UL 60950-1 (CULUS) Laser Safety EN60825 Translated Safety Statements Important: The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at www.alliedtelesis.com/support/software.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Contents Preface.........................................................................................9 Safety Symbols Used in this Document.......................................................................................10 Where to Find Management Software Updates and Product Information .............................11 Contacting Allied Telesis .....................................................................
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Contents Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating Updating the the the the the the the the the the the the the the the the the the the the the the the the the 802.3az EEE property......................................................70 ARP Offload property...
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figures Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure Figure 1. AT-2716POE Adapter.................................................
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 8
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Preface This guide contains instructions on how to install the AT-2716POE Fast Ethernet Fiber & PoE Adapter. Procedures that describe how to install and configure the driver software on the Windows XP, Windows Vista, and Windows 7 Operating Systems are provided.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Safety Symbols Used in this Document This document uses the safety symbols defined in Table 1. Table 1. Safety Symbols Symbol Meaning Caution Warning Description Performing or omitting a specific action may result in equipment damage or loss of data. Performing or omitting a specific action may result in electrical shock.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Where to Find Management Software Updates and Product Information New releases of management software are on the Allied Telesis web site. In addition, the installation and user guides are available for all Allied Telesis products in portable document format (PDF) on our web site. Both the management software and the product documentation are available at www.alliedtelesis.com/support/software/.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Contacting Allied Telesis This section provides Allied Telesis contact information for technical support as well as sales or corporate information. Online Support You can request technical support online by accessing the Allied Telesis Knowledge Base at www.alliedtelesis.com/supportcenter. You can use the Knowledge Base to submit questions to our technical support staff and review answers to previously asked questions.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 1 Introduction to the AT-2716POE Fast Ethernet Fiber & PoE Adapter This chapter provides an introduction to the AT-2716POE Fast Ethernet Fiber & PoE Adapter and discusses the following topics: “Functional Description” on page 14 “AT-2716POE Adapter Software Drivers” on page 16 13
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Functional Description The AT-2716POE Fast Ethernet Fiber & PoE Adapter is a highly integrated dual-port adapter based on Broadcom’s BCM5718 chipset. The primary data port is 100FX fiber. The secondary port is a 1 Gigabit copper port which can support Class 3 Power over Ethernet (PoE) devices. See Figure 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide LEDs The AT-2716POE adapter has two LEDs located on the copper port. See Figure 2. The left LED, labeled TX, indicates the link and activity status of the 1 Gigabit copper port that has PoE capabilities. The right LED, labeled FX, indicates the link and activity status of the 100FX fiber port. For a description of the LEDs, see Table 1. Table 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide AT-2716POE Adapter Software Drivers You can download the latest version of the software driver and our configuration for the AT-2716POE adapter from the Allied Telesis website at www.alliedtelesis.com/support/software. After you have accessed this website, enter the model number in the Search by Product Name box; for example, AT-2716POE. Then click Find.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 2 Installing the Hardware The AT-2716POE Fast Ethernet Fiber & PoE Adapter can be installed in any system with an appropriate PCIe slot.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Reviewing Safety Precautions Please review the following safety precautions before you begin to install the network adapter card. Note The indicates that a translation of the safety statement is available in a PDF document titled “Translated Safety Statements” on the Allied Telesis website at www.alliedtelesis.com/support/ software.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Warning The adapter is being installed in a system that operates with voltages that can be lethal. Before you remove the cover of your system, you must observe the following precautions to protect yourself and to prevent damage to the system components. Remove any metallic objects or jewelry from your hands and wrists. Use only insulated or non-conducting tools.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Checking the Contents of Your Shipment The following items are included with your adapter: Antistatic bag (used for protecting the adapter when stored or shipped). Keep the adapter in its packaging until ready for installation. Standard profile bracket Inform your network supplier of any missing or damaged items.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Pre-Installation Checklist Before you install an adapter card, do the following: 1. Check that your system has an appropriate open PCIe slot. 2. For the PoE feature, check that you system has an appropriate SATA or IDE power connector available on your system power supply harness. 3. Verify that your system is using the latest BIOS. 4. If your system is active, shut it down. 5.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Installing a Network Adapter Card The following instructions apply to installing an AT-2716POE adapter in most systems. If you need more information, refer to the manuals that were supplied with your system for details about performing these tasks on your particular system. Note To perform this procedure, you need to supply one Phillips-head screw. To install the network adapter card, perform the following procedure: 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 3. Select any appropriate empty, non-shared PCIe slot and remove the faceplate. If you do not know how to identify an appropriate PCIe slot, refer to your system documentation. Keep the faceplate in a safe place. You may need it for future use. See Figure 4. Figure 4. Removing the Faceplate from PCIe Slot Note If you cannot locate or know how to find an appropriate PCIe slot, refer to the documentation that came with your system.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Make sure the card is securely seated. See Figure 5. Figure 5. Inserting the Network Adapter Card Caution Do not use excessive force when seating the card, because this may damage the system or the adapter. If the card resists seating, remove it from the system, realign it, and try again. 6. Secure the network adapter card to the chassis with a Phillips-head screw (not provided) as shown in Figure 6. Figure 6.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 7. Depending upon model order connect an appropriate unused power connector from the system power supply harness to the AT-2716POE SATA or IDE power connector receptacle as shown in Figure 7. Figure 7. Installing System PS SATA Harness connector to AT2716POE 8. Replace the system’s cover and secure it with the screws removed in Step 2. 9. Disconnect any personal antistatic devices. 10. Power the system on.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Connecting the Network Cables The AT-2716POE adapter has one fiber optic connector to connect to the data network and one copper PoE port for attaching the adapter to a compatible link partner. The fiber optic connector requires a fiber optic cable. The copper port requires a twisted-pair cable. For pin signals and pinout information, see “10/100/1000Base-T Twisted-Pair Port Connectors” on page 88.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 8. AT-2716POE Fiber Port 2. Connect the other end of the cable to the appropriate Ethernet network port or fiber optic port. After the cable is properly connected at both ends, the adapter port LED is functional. See Table 1 on page 15 for a description of adapter port LED operation.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Checking Warranty Registration All Allied Telesis warranties are subject to and provided only on the terms and conditions set out in the Allied Telesis Limited Warranties listed on the Allied Telesis website at www.alliedtelesis.com/support/warranty.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 3 Installing Windows XP NDIS Driver Software This chapter describes how to install the Windows XP driver software. This chapter contains the following sections: “Installing the Driver Software” on page 30 “Uninstalling the Driver Software” on page 38 After you install the driver software, you can modify the configuration properties as described in Chapter 7, “Setting Advanced Properties” on page 61.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Installing the NDIS Driver Software The system automatically detects new hardware and prompts you to install the driver software for that device when a Windows XP system first boots up. The same windows are displayed after an existing device driver is removed.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide To install the adapter software on a Windows XP system, do the following: 1. Download the software drivers from the Allied Telesis website to a folder on your computer. For specific instructions, see “Where to Find Management Software Updates and Product Information” on page 11. 2. Start up you Windows XP system and log in. The initial Found New Hardware Wizard window is displayed. See Figure 9 Figure 9.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 10. Found New Hardware Wizard Window: Search and Installation Options 4. Click the check box for Include this location in the search. 5. Click Browse and locate the path of the software driver. 6. Click Next. 7. When the software installation is complete, click Finish to close the wizard and complete the software installation.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Updating the This section provides a procedure for updating the adapter software for Adapter Software Windows XP Operating Systems. To obtain the latest AT-2716POE adapter software drivers, you can download them from the Allied Telesis website at www.alliedtelesis.com/ support/software. For specific instructions, see “Where to Find Management Software Updates and Product Information” on page 11.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 11. Windows XP Professional Start Window 3. Select Run from the menu and enter the following command: devmgmt.msc See Figure 12 for an example of the Run Window. Figure 12.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide The Device Manager Window is shown in Figure 13. Figure 13. Device Manager Window (Network adapter folder is collapsed) 4. In the Device Manager window, click the + next to the Network adapters folder. The selection expands to show the list of installed network adapter cards. 5. Right click on the AT-2716POE adapter and select Update Driver.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide The Welcome to the Hardware Update Wizard window opens, as shown in Figure 14. Figure 14. Welcome to Hardware Update Wizard Window 6. Click No, not this time to copy the driver software from your PC. 7. Click Next. The Second New Found Hardware Wizard Window opens, as shown in Figure 15. Figure 15. Hardware Update Wizard Window 8. Click Install from a list or specified location (Advanced).
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 9. Click Next. 10. If you are prompted to specify the location of the software driver, click Browse (do not use the text field) and locate the path. After you install the driver software, you can modify the configuration properties. See Chapter 7, “Setting Advanced Properties” on page 61.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Uninstalling the Driver Software Caution Before uninstalling the Allied Telesis device, be sure to capture all Advanced Property settings because the properties are lost during the uninstall process. To uninstall the adapter software from your system, perform the following procedure: 1. Start your Windows XP system and log in. Note You must have Administrator privileges to remove the driver software. 2.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 4 Installing the Windows Vista and Windows 7 NDIS Driver Software This chapter describes how to install the Windows Vista and Windows 7 driver software for the AT-2716POE adapter. The installation procedures are identical for the 32-bit and 64-bit Windows Operating systems.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Installing the Driver Software After you physically install an AT-2716POE adapter and turn on the computer, the system detects the new hardware and asks for a software driver when the Windows operating system first boots up. Shortly after you log in, you need to install the driver software. To install or update the driver software, you must have administrative privileges.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 3. Enter the following command in the Run window: mmc devmgmt.msc 4. Click OK. The Windows Device Manager window is displayed. For an example of the Device Manager window, see Figure 17. Figure 17. Windows Device Manager Window 5. Open the Network Adapters folder clicking on the “+” next to the Network adapters folder. 6. The selection expands to show the list of installed adapter cards on your PC.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Installing the AT- The procedure in this section describes how to install the driver software 2716POE Driver for the AT-2716POE adapter. 1. Open the Device Manger. Refer to “Opening the Device Manager” on page 40 for more information. 2. Open the Network Adapters folder by clicking on the “+” symbol next to the Network adapters folder. The selection expands to show the list of installed adapter cards on your PC.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 5. Click Browse my computer for driver software. The Update Driver Software - Ethernet Controller: Browse for Driver\ Software Window is displayed. See Figure 20 on page 43. 6. Click Browse to search your computer for the location of the driver software. See Figure 20. Figure 20. Update Driver Software: Ethernet Controller: Browse 7. Click Next. A confirmation message is displayed. See Figure 21. Figure 21.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Uninstalling the Driver Software Before physically removing an adapter from your system, you need to uninstall the driver software first. The procedure in this section describes how to uninstall the driver software. Note You must have Administrator privileges to remove the driver software.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 3. To select the Device Manager in the Windows 7 Operating System, select the Start button. See Figure 17 on page 41. Figure 22. Windows 7 Search Box 4. Enter the following command: mmc devmgmt.msc The Device Manager window is displayed. For an example of the Device Manager window, see Figure 18 on page 42. 5. To select the Device Manager in the Windows Vista Operating System, select the Start menu.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide See Figure 19 on page 42 for an example of the Windows Vista Start menu. Figure 23. Windows Vista Start Menu 6. From the Start Menu, select Run. The Windows Vista Run window is displayed. See Figure 16. Figure 24. Windows Vista Run Window 7. Enter the following command in the Run window: mmc devmgmt.msc The Device Manager Window is shown in Figure 18 on page 42. 8.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide The selection expands to show the list of installed network adapter cards. 9. Right-click on the adapter you want to remove and select Uninstall. A Confirm Device Removal window opens. 10. Click OK to complete the uninstall. Note Not all of the driver files are removed as a result of this procedure. You can remove additional drivers and installation files by selecting the checkbox to remove these files.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide INTENTIONALLY LEFT BLANK 48
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 5 Installing the AT-2716POE AT-Mux CONFIGURATION Application This chapter describes how to install the AT-2716POE AT-Mux CONFIGURATION application on the Windows XP, Windows Vista, and Windows 7 driver software on an AT-2716POE adapter. The installation procedure is identical for all of the above mentioned Windows Operating systems.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Virtual LANs and the AT-2716POE AT-Mux Configuration Utility The AT-2716POE adapter is IEEE 802.1Q-compliant and is designed to support virtual LANs (VLANs) and tagged packets. A VLAN is an independent traffic domain where traffic generated by the nodes of a VLAN is restricted only to nodes that are members of the same VLAN.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide on that assigned port. The adapter discards all untagged packets on that port as well as any tagged packets with VIDs that do not match the VIDs assigned to the card. Either one or both adapter ports can be tagged with the same or different VIDs.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide INTENTIONALLY LEFT BLANK 52
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Installing the AT-2716POE AT-Mux Configuration Utility 1. Double click Setup.exe for 32 bit operating system or Setup64.exe for 64 bit operating system to start the AT-2716POE AT-Mux Setup Wizard. See Figure 28. Figure 28. Welcome to the AT-2716POE AT-Mux Setup Wizard Window 2. Click Next. The Confirm Installation window is displayed. See Figure 29.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 29. Confirm Installation Window 3. Click Next. The Installing AT-2716POE Window is displayed. See Figure 30. Figure 30. Installing AT-2716FXTP Window 4. Click Next. The Installation Complete window is displayed. See Figure 31 on page 55.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 31. Installation Complete Window 5. Click Close.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Configuring the AT-2716POE AT-Mux Configuration Utility To launch the AT-2716POE AT-Mux Configuration Utility, perform the following steps: 1. Click on Start. 2. Click on Control Panel 3. Run the ATI AT-Mux Setup program (AT Vlan) from the Control Panel. The AT-2716POE AT-Mux Configuration window appears. Figure 31.1. AT-2716POE VLAN Configuration window 3. Double-click the fiber or copper port.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 6 VoIP Configuration Example This chapter describes an example of the AT-2716POE adapter supporting both data and VoIP Ethernet traffic. VoIP Support The AT-2716 POE is a two port adapter with a 100FX fiber port and a 100TX copper port capable of supporting a Class 3 PoE device.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 32. VLAN topology In Figure 32, the VoIP phone is attached to the AT-2716POE copper port. However, many VoIP devices cannot recognize VLAN tagged packets. The AT-2716POE Configuration Utility handles this situation by allowing you to enable the VLAN setting on the copper port and assign a unique VLAN ID to the port for the VoIP traffic.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Example 2 shows a scenario where non VLAN aware VoIP phone is present. In this scenario, the copper port of the AT-2716 POE is responsible for tagging the VoIP data with VLAN 2. This data is then sent through the fiber port to the network backbone. Network data continues to be tagged with VLAN 1 and is segmented from VoIP data. Example 3 shows a scenario where a VLAN aware phone is present and has VLAN tagging enabled.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Table 4 shows all of the allowable tagged vs. non-tagged configurations available. Not all possible combinations are supported. Table 4.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 7 Setting Advanced Properties Although the default values are appropriate in most cases, you can change any of the available options to meet the requirements of your system. The Windows Advanced Properties are accessible from the Advanced Tab.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Accessing the Advanced Tab To modify the configuration properties of the Windows Operating Systems, you must access the Advanced Tab. Depending on your operating system, there are several ways to do this.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 33. System Properties Dialog Box 4. Click on the Advanced Tab.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Selecting the To select the Advanced Tab in the Windows 7 Operating System, do the Advanced Tab in following: Windows 7 1. Select the Start button. See Figure 34. Figure 34. Windows 7 Search Box 2. Enter the following command: mmc compmgmt.msc The Device Manager window is displayed. For an example of the Device Manager window, see Figure 35 on page 65.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 35. Device Manager Window 3. Open the Network Adapters folder. The list of installed adapters is displayed. 4. Right click on the Allied Telesis AT-2716POE adapter. The adapter window is displayed.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide The Advanced tab is shown in Figure 36. Figure 36. Advanced Tab 5. Select the Advanced tab. The Advanced tab is shown in Figure 36 on page 66. Selecting the In the Windows Vista Operating System, you access the Advanced Tab Advanced Tab in through the Device Manager. Windows Vista To select the Device Manager in the Windows Vista Operating System, do the following: 1. Select the Start menu.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide See Figure 37 for an example of the Windows Vista Start menu. Figure 37. Windows Vista Start Menu 2. From the Start Menu, select Run. The Windows Vista Run window is displayed. See Figure 38. Figure 38. Windows Vista Run Window 3. Enter the following command in the Run window: mmc devmgmt.msc 4. From the Computer Management Window, select Device Manager in the left panel. The Device Manager window is displayed.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 5. Open the Network Adapters folder. The list of installed adapters is displayed. 6. Right click on the Allied Telesis AT-2716POE adapter. The adapter window is displayed. 7. Select the Advanced tab. The Advanced tab is shown in Figure 36 on page 66.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Modifying Advanced Properties In most cases, the default property values available on the Advanced Tab are appropriate although you can change any of the available options to meet the requirements of your system. You must have Administrator privileges to modify the driver software.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Updating the 802.3az The “802.3az EEE” property property will allow the adapter to enter Low EEE property Power Idle mode when network utilization is low. 1. In Microsoft Windows, right-click the Network Adapter in Network Connections and, then click Properties. 2. Click the Configure button and then the Advanced tab. 3. Set the "802.3az EEE " parameter to Disable or Enable. The default setting is Disable.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 3. Set the "Flow Control" parameter to Auto, Disabled, Rx Enabled, Rx & Tx Enabled, or Tx Enabled. The default setting is Auto. Updating the Interrupt The “Interrupt Moderation” property will cause the network device to Moderation property send interrupt requests only after multiple packets have been received and not immediately upon receipt of a packet. 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Updating the Large The “Large Send Offload v2 (IPv4)” property allows for configuring LSO Send Offload v2 using version 2 of the IPv4 protocol. (IPv4) 1. In Microsoft Windows, right-click the Network Adapter in Network Connections and then click Properties. 2. Click the Configure button and then the Advanced tab. 3. Set the "Large Send Offload v2 (IPv4)" parameter to Disable or Enable. The default setting is Enable.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 1. In Microsoft Windows, right-click the Network Adapter in Network Connections and then click Properties. 2. Click the Configure button and then the Advanced tab. 3. Set the Priority & VLAN setting to Priority & VLAN Disabled, Priority & VLAN Enabled, Priority Enabled, or VLAN Enabled. The default setting is Priority & VLAN Enabled.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Updating the The “TCP/UDP Checksum Offload (IPv6)” property allows configuring TCP/UDP Checksum checksum offload for the IPv6 protocol. Offload (Ipv6) 1. In Microsoft Windows, right-click the Network Adapter in property Network Connections and then click Properties. 2. Click the Configure button and then the Advanced tab. 3.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 2. Click the Configure button and then the Advanced tab. 3. Set the "VMQ VLAN Filtering" parameter to Disable or Enable. The default setting is Disable. Updating the Wake The "Wake Up Capabilities" parameter allows the user to set the Up Capabilities adapter to wake up from a low power mode when it receives a network property wake up frame. There are two wake up frames: Magic Packet and IP frame. 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Chapter 8 Troubleshooting This chapter describes troubleshooting procedures and discusses the following topics: “Hardware Diagnostics” on page 77 “Checking Port LEDs on the Adapter” on page 78 “Troubleshooting Checklist” on page 79 “Testing Network Connectivity” on page 80 “Software Problems and Solutions” on page 82 76
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Hardware Diagnostics Loopback diagnostic tests are available for testing the adapter’s hardware under Microsoft DOS operating system and are available for download at the product’s website. These tests provide access to the adapter's internal or external diagnostics, where packet information is transmitted across the physical link.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Checking Port LEDs on the Adapter The adapter has two LEDs, one LED for each port and indicates network link and network activity. Before the port LEDs can provide troubleshooting information, the adapter must be connected to the network and the network drivers for your particular operating system must be installed. 1. Verify that the adapter driver software has been installed and that the adapter is connected to a network. 2.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Troubleshooting Checklist The following checklist provides recommended actions to take to resolve problems installing the Allied Telesis AT-2716POE adapter or running it in your system. Warning Before opening the cabinet of your system for removing or inserting the adapter, please review all precautions outlined under “Reviewing Safety Precautions” on page 18. Inspect all cables and connections.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Testing Network Connectivity The following section describes how to test network connectivity for Windows XP, Windows Vista, and Windows 7 networks. Use the ping command to determine if network connectivity is working. Note When using forced link speeds, make sure that both the adapter and the switch are forced to the same speed. Or, make sure both partners are configured for Auto-Negotiation.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Figure 41. Command Window with ipconfig /all displayed 4. Type ping from the command line, then press Enter. The network connectivity information is displayed, as shown in Figure 42. Figure 42.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Software Problems and Solutions This section lists problems and solutions for the Microsoft Remote Installation Service (RIS), Windows Operating Systems, and miscellaneous issues. Microsoft Remote Problem: Microsoft Remote Installation Service (RIS) installation fails for Installation Windows XP.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Appendix A Specifications Physical Specifications This section lists the dimension and weight of AT-2716POE adapter. Dimensions: 14.09 cm x 5.6 cm (5.5 in x 2.2 in) Weight: 68 g ( 2.4 oz) Environmental Specifications The following environmental specifications apply the AT-2716POE adapter.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Storage vibration, peak acceleration: 0.25g (5 to 500 Hz) (Sweep Rate = 1 octave/ min.) Power Specifications The operating voltage specification in this section applies to the AT2716POE adapter. Power Consumption: 2.5 Watts (without PoE) @ +3.3V Operating Specifications The following operating specifications apply the AT-2716POE adapter.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 10/100/1000Base-T Twisted-Pair Port Connectors This section lists the pin signals for the 10/100/1000Base-T twisted-pair ports for the AT-2716POE adapter. Figure 43 illustrates the pin layout to an RJ-45 connector and port. Figure 43. RJ-45 Connector and Port Pin Layout Table 5 lists the RJ-45 pin signals when a twisted-pair port is operating in the MDI configuration. Table 5.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Table 7.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Appendix B Cleaning Fiber Optic Connectors The fiber optic connector consists of a fiber optic plug and its adapter. The end of the fiber optic cable is held in the core of the ferrule in the plug. Light signals are transmitted through the core of the fiber.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Cleaning Fiber Optic Connectors Using a Cartridge-Type Cleaner Fiber optic cartridge cleaners are available from many vendors and are typically called “cartridge cleaners,” as shown in Figure 46. Figure 46. Cartridge Cleaner Note Do not use compressed air or aerosol air to clean a fiber optic connector. To clean a fiber optic connector using a cartridge cleaner, perform the following procedure. 1.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Note Rub the ferrule tip on the cleaning surface in one direction only. 3. When you reach the end of the cleaning surface, pick up the ferrule tip, rotate and place it at the top and rub downwards at least 2 times. Caution Failing to pick up the ferrule tip when you reach the bottom of the cleaning surface can result in static electricity that can damage the fiber optic cable. 4. If desired, repeat steps 3 and 4. 5.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide Using a Swab Specially treated swabs, known as stick cleaners, are available for cleaning inside connector adapters or hard-to-reach ferrule tips. These swabs, often referred to as “lint free” or “alcohol free” swabs, are available from many vendors, as shown in Figure 48. Stick cleaners are available in both 2.5 mm and 1.25 mm sizes for use on SC and MU connectors respectively.
AT-2716POE Fast Ethernet Fiber & PoE Adapter Installation and User’s Guide 3. If a fiber inspection scope is available, use the scope to inspect the connector to make sure that it is clean and to check for scratches, pits, or other problems that may affect performance. Note Always keep a dust cap on a fiber optic cable when it is not in use. Warning Do not stare into the laser beam. L2 Warning Do not look directly at the cable ends or inspect the cable ends with an optical lens.