8.1 CONTROL MODULE TROUBLESHOOTING
Will Not Power Up
Verify the wiring per the instructions in the manual (sections 2.3 - 2.4).
+ROGGRZQWKHPDQXDOUHVHWEXWWRQIRUVHFRQGVWRIRUFHDȊKDUGUHERRWȋ
Unplug the power cord for 60 seconds and restart.
Call Sigalarm for remote assistance if available.
Frozen Screen
Try adjusting the setpoint using the manual buttons. If the setpoint increases or
decreases the touch screen is frozen, but not the control module. Power cycle
the unit to resolve the situation. Never touch the screen while the system is
powering up to avoid this problem.
+ROGGRZQWKHPDQXDOUHVHWEXWWRQIRUVHFRQGVWRIRUFHDȊKDUGUHERRWȋ
Cannot Adjust Setpoint
Verify that the lock setpoint feature in the admin screen is not selected.
Verify that the max setpoint parameters in the admin screen are set in such
a way that allows adjustment.
8.2 SENSOR TROUBLESHOOTING
No Data Reading
Check that the sensor is turned on.
Verify that the battery is charged using test points on the board.
The distance between the sensor and the control module may be too great,
try repositioning.
Sensor Reading Is 0
It is common to have a reading of zero, it is only a problem if the sensor is
near voltage.
Test that the sensor is detecting voltage by plugging in an extension cord and
moving it near the sensor, check that the reading increases.
The voltage may be too low to detect at that distance.
The power line may be too far away for the sensor to detect at that voltage.
8. TROUBLESHOOTING