If multiple lines are present, the Sigalarm should be calibrated to the lowest
voltage line, and additional preventative measures may need to be utilized.
The operator MUST fully understand how the Sigalarm is installed, operates, and
its limitations before use.
It is highly recommended that a Sigalarm distributor or an equally competent
person complete installations.
Prior to use, operator training should be done by Sigalarm, its representatives, or a
competent person.
When operating in close proximity to high voltage power lines, vehicles should be
prohibited from traveling between the boom and power line.
$GMXVW WKH 6LJDODUP VHWSRLQW ZKHQ WKH ERRP DQJOH DQGOHQJWK LVVLJQLȴFDQWO\
GL΍HUHQWWKDQWKDWXVHGIRUWKHODVWVHWWLQJ
It is dangerous to operate any high lift vehicle beneath or above high voltage
lines.
!
WARNING NOTES
GREATER THAN 10FT
Sigalarm systems should not be used on equipment operating closer
than 10 feet to a power line.
5.3 REMOTE CONTROL OPERATION
Some units are equipped with remote control capabilities. Those units can be
operated as follows: The control module will automatically go into max when
power is applied. The operator can depress the reset button from the remote key
fob. If a danger status occurs the operator can depress the override button on the
remote key fob. The control module will then display an override countdown. The
override countdown keeps the unit in a warning state for 15 seconds to allow the
operator to pull away from the line.
5.4 SYSTEM RESET
The reset button and icon returns the unit to the last setpoint. The reset must be
selected once every time power is applied to the control module. The displayed
setpoint will autosave every 10 seconds. Depressing the reset button for 15
VHFRQGVZLOOȊKDUGUHVHWȋWKHFRQWUROPRGXOH