Installation and Operation Manual
27
SIGALARM INSTALLATION AND OPERATION MANUAL / GENERATION 4 WIRELESS / VERSION 4.2
BELOW SET
A below set status occurs when all of the
sensors have a reading numerically lower
than the displayed setpoint. This means
WKHHTXLSPHQWLVLQWKHGHȴQHGZRUN]RQH
WARNING
A warning status occurs when one or more
sensors are within 80% of the setpoint. This
means the equipment is getting closer to
but has not yet reached the danger zone.
DANGER
A danger status occurs when one of the
sensor readings matches the setpoint. This
means the equipment has crossed into the
danger zone. No setpoint adjustments can
be made during a danger status.
NO DATA
A no data status occurs when the sensor
is not transmitting data to the control
module for more than two seconds. This
means there is no protection zone around
WKH ȊGRZQȋ VHQVRU DQG WKH HTXLSPHQW
is no longer detecting voltage. Do not
operate equipment with a no data status.
The system will beep alerting the operator
of a no data status. See additional no data
notes in the troubleshooting section.