SETPOINT
The operator must decide what setpoint is appropriate for each and every
jobsite.
5.2 OPERATING PROCEDURES
Powering up: :KHQ SRZHU LV ȴUVW DSSOLHG WKH FRQWURO PRGXOH ZLOO VHDUFK IRU
sensors. No data will appear while connectivity is in progress (approx. 2 seconds).
Once sensors are connected the control module will go into a maximum setting. If
any power lines are in the vicinity, the alarms will sound. The operator must select
the reset button to revert the system to the last displayed set point.
The operator must decide what setpoint is appropriate for each and every jobsite.
To adjust the setpoint, position the equipment at the desired location where the
RSHUDWRUZRXOGOLNHDQDODUPVWDWHWKHQGHSUHVVWKHȊRQHWRXFKȋEXWWRQ7KLVZLOO
change the setpoint to the greatest numerical sensor reading +5 at that position.
When adjusting the setpoint, always position the equipment far enough away from
the power line to give the operator time to react.
!
IF MULTIPLE LINES ARE PRESENT, THE SIGALARM SYSTEM
SHOULD BE SET TO THE LOWEST VOLTAGE LINE, AND
ADDITIONAL PRECAUTIONS MAY BE REQUIRED.
The Sigalarm system should be set to give a warning no closer than the minimum
approach distance or MAD from the power line. Setpoint adjustments can also
be made utilizing the increase or decrease buttons. Use a spotter to help you
determine a safe position while adjusting the setpoint.
!
SIGNIFICANT CHANGES IN BOOM LENGTH AND/OR ANGLE
MAY REQUIRE A SETPOINT ADJUSTMENT THAT DIFFERS
FROM THE INITIAL SETPOINT SELECTION AT SETUP.