ADMIN SCREEN FEATURES (ALL PASSWORD PROTECTED)
Setpoint: Maximum setpoint parameters can be set to limit the operator’s ability
to increase the setpoint from the Home Screen. For example: if the admin selects
55 as the maximum setpoint, the operator can only increase the setpoint to 55 or
less. This also limits the one touch feature to 55 or less.
Volume Max: The volume maximum can be set to limit the operator’s ability to
increase the volume of the external speaker. For example: vehicles working in
residential neighborhoods may require a softer alarm. This setting should never
bet set low enough that ground personnel cannot hear the external speaker. This
feature should always be set to the highest tolerable maximum.
Volume Min: The volume minimum can be set to limit the operator’s ability to
decrease the volume. A setting of 1 means the operator can adjust the volume of
the external speaker all the way down to silent. This is NEVER recommended. It is
imperative that ground personnel can hear the external speaker.
Lock Setpoint: The lock setpoint feature can be selected to leave the operator with
no ability to increase or decrease the setpoint.
Disable Alarm Lockout: This feature will bypass normal relay continuity in
ȊGDQJHUȋPRGHIRUHPHUJHQF\VLWXDWLRQVVLPLODUWRDPDQXDORYHUULGH:KHQWKLV
ER[LVVHOHFWHGUHOD\FRQWLQXLW\ZLOOEHFRQȴJXUHGDVVKRZQEHORZ3URFHHGZLWK
extreme caution when utilizing this feature.
Danger status with
ȊGLVDEOHDODUPORFNRXWȋVHOHFWHG
Red Black White
Relay Port 3 & 4
12
3
123
DISABLE ALARM LOCKOUT
Disable alarm lockout is only relevant if 2.0WRLY cable is installed & only
DHFWVUHOD\