Installation and Operation Manual
15
SIGALARM INSTALLATION AND OPERATION MANUAL / GENERATION 4 WIRELESS / VERSION 4.2
Relay Port 3 & 4 Sigalarm Status
POWER OFF
NORMAL
OPERATION
WARNING
DANGER
Front view of control
module ports
Relay Port 1 & 2
12
3
12
3
123
123
123 123
123123
123
123
RELAY INSTALLATION EXAMPLE
Auto shut down: To stop hydraulics moving when a danger state occurs
connect the supplied relay cable (2.0wrly) to relay port 3 on the rear of the
control module. The blunt end of the (2.0wrly) cable should be wired to
the equipment’s hydraulics using Pin 1(red) and 2(black) so the circuit is
interrupted and hydraulic movement is stopped in a danger status.
*Auto shut down in never recommended for equipment moving a load*
Use the relay diagram to customize the installation to your needs.
SIGALARM RELAY STATUS DIAGRAM
SIGALARM
STATUS
DEFINITION OF STATUS RELAY 3 RELAY 4 RELAY 1 RELAY 2
PINS
1 & 2
PINS
1 & 3
PINS
1 & 2
PINS
1 & 3
PINS
1 & 2
PINS
1 & 3
PINS
1 & 2
PINS
1 & 3
SRZHUR
no power supplied
to control module
open closed open closed open closed open closed
normal
operation
sensor status below
setpoint value
closed open closed open open closed open closed
warning
approaching
setpoint value
closed open closed open closed open closed open
danger
at or above
setpoint value
open closed open closed closed open closed open