Installation manual
Chapter 5: Configuring the CopperJet
CAS: Channel Associated Signaling (CAS) is used in bit-based schemes
where dedicated signaling bandwidth is required for every
connection.
Profile: Select ITU-T (voice over AAL2) or ATM-Forum (AF–voice traffic
over ATM (VTOA)). Profile Source and Identifier are only used for
BLES signalling (both CAS and ELCP). For voice gateways with an
ADPCM only mode (for all UUI values 0..15) the special atmforum
profile number 13 is used.
Proprietary test mode: This mode enables the internal PBX functionality for testing
the Voice ports.
Voice port 1: number 101
Voice port 2: number 102
Voice port 3: number 103
Voice port 4: number 104
When finished configuring VoDSL, click on Apply. Go to the Configuration menu and click
on Save config to save the new settings into the CopperJet.
5.17.2 Advanced Voice over DSL Configuration
Configuration of advanced Voice over DSL settings in the CopperJet IAD’s is done through
TELNET. To access the TELNET configuration mode, start a TELNET session from your
computer (i.e. TELNET <ip-address>) and enter your username and password (default
username and password are admin, admin). To access the advanced settings enter the
following commands:
console enable [enter]
iad [enter]
The prompt has changed into <ip-address> iad>.
5.17.2.1 Flash on hook timing
Because the requirements of flash on hook timing differ a lot per country, the minimum
and maximum hook flash time can be configured.
Syntax: flashmin <value>
Minimum flash-on-hook time in milliseconds after a hook-flash is detected. Below this
value no flash nor hook state change is detected.
Syntax: flashmax <value>
Maximum flash-on-hook time in milliseconds before a hook flash is detected. Above this
value a hook state change is detected.
Note: that if flashmax < flashmin, hook flash detection is disabled. Flashmin can be used
to set the minimum time a hook state change is detected.
Example: to set the minimum flash-on-hook timing to 60 milliseconds enter the following
command:
flashmin 60 [enter]
Example: to set the maximum flash-on-hook timing to 200 milliseconds enter the following
command: