Installation manual
Chapter 5: Configuring the CopperJet
it will also have an idle timeout of 10 minutes, whether the session is TCP, UDP or fake
(i.e., anything else). Until that session expires, the Management Station will not be
disabled.
Note: That a TCP session may be terminated before the end of the idle timeout, since TCP
is a connection-oriented protocol and the end of the TCP session will be detected by
the Security software.
5.3.5 Update Firmware and Restore Configuration Profile
The Update page enables you to upload new firmware release and/or restore saved
configuration profiles. From the System menu click on Update. The System Software
Update/Configuration Profile Update page is displayed.
To upload new firmware, enter the firmware filename at the New Firmware Image text box
and type the name of the firmware file that you wish to upload (*.tbi). If you do not know
the filename details, click on the Browse button and locate the file using the Choose file
box. Click on the Update button. The page is refreshed with a Firmware upload message
and details of the number of bytes uploaded.
Note: After a firmware update you need to reset the CopperJet to it’s Vendor default
settings (see section 5.3.7 how to do this), otherwise some parameters of the new
firmware don’t take effect. The current configuration will be lost. Before updating the
firmware, make a backup of the configuration. How to make a backup go to section
5.3.6.
Note: Depending on the current and new firmware version, you may be required to enter a
Configuration Profile also.
To restore a saved configuration profile, enter the profile filename at the New
Configuration Profile text box and type the name of the configuration profile that you wish
to restore (*.tpr). If you do not know the filename details, click on the Browse button and
locate the file using the Choose file box. Click on the Update button. The page is refreshed
with a Configuration upload message and details of the number of bytes restored.