Service manual
800168 79
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Section 4
Grounding
36. WALL RECEPTACLE POLARITY CHECK.
(Figure 15).
Figure 15
W011GE3A
Neutral
Side
Round
Grounding
Prong
L1
Neutral
Ground
0
V.A.C.
115±12
V.A.C.
115±12
V.A.C.
NOTE: Have a qualified 
electrician check polarity of 
wall receptacle. If a voltage 
reading is measured other 
than that illustrated, the 
qualified electrician should 
correct the problem.