Service manual
62 800168
Section 3 Troubleshooting (NetMaster Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
27. MICROWAND DOES NOT COMMUNICATE WITH CONTROL
Attempt to communicate with the 
electronic control from the Microwand.
Is there 
acknowledgement of 
any kind from the 
control?
Aim the 
Microwand closer 
and try again.
No
Yes
Does the Microwand 
prompt: Control 
Mismatch error ?
Is there any control 
response?
Yes
Check the following:
- Microwand battery voltage
- Blockage of IR window on control
- Attachment of IR cup to 
Microwand.
No
Make sure 
Microwand 
selection was for 
the proper 
machine type and 
control generation 
type.
Yes
No
Does the electronic 
control display "E:OF" 
or "-C-"?
-C-
Communication 
sequence checks 
out properly.
Change electronic 
control and repeat 
procedure.
Has IR communication 
been turned off?
E:OF
No
Yes
Turn IR 
communication on 
(refer to 
programming 
manual).
FLW296S