Service manual
46 800168
Section 3 Troubleshooting (MDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
20. NO VISIBLE DISPLAY ON CONTROL
Control Has No Visible Display
The electronic control has no 
LED or VFD functioning on 
the control board.
Is the power cord 
plugged in?
Plug unit into an 
outlet and check 
for proper supply 
voltage.
No
Yes
(1)
No
Is there 24 Volt
 AC at the output side of 
the transformer?
Is there 
120 AC to the 
primary of the 
transformer?
No No
(2) (3)
Check wiring to 
the primary of the 
transformer.
Yes Yes
Correct wiring 
between 
transformer and 
control board.
Replace 
transformer.
Make sure "H1" 
connector is 
seated properly. 
Replace control.
Yes
Is there 24 Volt AC 
across terminals "H1-1" 
and "H1-3" control 
board?
FLW298S 