Service manual
44 800168
Section 3 Troubleshooting (MDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
19. COINS IGNORED WHEN ENTERED
Coins Ignored When Entered.
Start Coin Drop Diagnostic Test. Refer 
to programming manual.
Reset control to 
ready mode.
Yes
No
Is "H7" connector 
properly seated on the 
control board?
No
Properly reseat 
connection and 
conduct diagnostic 
test again.
Yes
From the coin drop, is 
the 3-pin connector 
properly plugged in?
Yes
No
Properly reseat 
connection and 
conduct diagnostic 
test again.
Are the wires exiting the 
coin drop optical sensor 
cracked or broken?
Replace electronic 
control.
Replace the 
coin drop.
Yes
No
Does the count on
the display increment 
properly after entering 
coins?
FLW297S
Start Production Test Cycle.