Section 3 Troubleshooting (EDC Models)
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
15. DOOR LOCKED, MOTOR DOES NOT RUN (E:DF ON DISPLAY)
Replace 
motor.
Is 
120 Volt AC 
present at terminals 
1-3 on transformer?
Is 
240 Volt 
present on the 
motor control at terminals 
FS3 to FS2?
Is 
20 Volt AC
present on the motor 
control at terminals 
H1-7 to FS2?
Is 
120 Volt AC 
present at terminals 
H3-5 to FS2 on the 
electronic display?
Replace 
electronic 
control.
(1)
YES
YES
YES
NO
NO
NO
NO
Using an Ohmmeter, 
check white wire and brown/
yellow wire coming into 
transformer for broken/poor 
connection.
YES
Using an Ohmmeter, check 
red wire from transformer 
to FS3 on motor control 
board for broken wire/poor 
connection. If none found, 
replace transformer.
Using an Ohmmeter, 
check red/black wire 
from transformer to H1-7 
on motor control board 
for broken wire/poor 
connection. If none 
found, replace 
transformer.
(2)
Is there
continuity?
Check continuity at terminal strip on motor:
TACH INPUT Terminals 6-7 Approximately 15 Ohms
BRUSHES Terminals 4-5 Less than 70 Ohms
Winding Terminals 1-3 Approximately 1.1 Ohms
Winding Terminals 1-2 Approximately 2.0-2.4 Ohms
Winding Terminals 2-3 Approximately 3.4 Ohms
*Resistance values may vary 
depending on type of meter used.
NO
Replace 
motor.
YES
MOTOR
Using an 
Ohmmeter, check 
for continuity between each 
terminal and the motor 
housing.
NO
Is there
continuity?
YES
(3)
(4)
Is 
there continuity 
through the motor harness 
from plug H-2 and H-5 on the motor 
control, to the plug at the 
motor?
NO
Replace 
harness.
YES
Is the 
fuse blown on the 
motor control 
board?
YES
Replace 
fuse.
NO
Does 
the machine 
run now?
Replace motor 
control board.
NO
Replace motor 
control board.
TRANSFORMER