Service manual
800168 11
Section 3 Troubleshooting
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the washer is properly grounded.
W003
WARNING
b. Electronic Coin Drops:
If coin drop is not accepting coins, perform the 
following:
(1) Clean coin drop. Refer to Paragraph 68.
(2) Test and replace tension spring using the 
following instructions.
REMOVE COIN DROP FROM MACHINE
(1) Disconnect electrical power to machine and 
drop.
(2) Remove coin drop from machine.
TEST TENSION SPRING
(1) Push coin return button to open and close 
coin drop cover to clear possible coin jams. 
Refer to Figure 2. 
(2) Manually hold down coin drop cover and 
insert coin. Refer to Figure 3.
(3)  If coin drop now operates properly, replace 
tension spring using instructions on 
following pages.
REPLACE TENSION SPRING
(1) Move tension spring downward until cover 
catch is free. Refer to Figure 4.
(2) Open cover for coin drop.
(3) Place a small flathead screwdriver under 
right side of tension spring and lift up. 
Refer to Figure 5.
(4) Use screwdriver to move spring 
approximately 3 mm to left.
Figure 2
Figure 3
MIX7B
Coin Drop 
Cover
Coin Return 
Button
MIX6B
Coin Drop 
Cover
Figure 4
Figure 5
DRY2088N
Cover Catch
MIX2B
Small Flathead 
Screwdriver
Right Side of 
Tension Spring
Left Tab