65. MOTOR BELT TENSION
NOTE: Belt adjustment procedures are done
through front of washer, however, as an option,
washer can be moved from its location and belt
adjustment can be done through lower access panel
opening at rear of washer.
a. While supporting lower front access panel,
remove two screws from bottom edge of access
panel and remove panel. Refer to Figure 26.
b. Working through the lower front access door
opening, place a locking pliers on the metal rod
and loosen the two adjusting bolts. Refer to
Figure 47. Repeat procedure to loosen the two
pivot bolts. Refer to Figure 47.
c. Pull down on motor to increase belt tension.
Use a Burroughs belt gauge to obtain proper
tension. Proper belt tension is obtained when
belt can be deflected approximately 1/4 inch
(6.35 mm) from normal position when
moderate pressure 50 to 60 pounds (22.68 to
27.22 Kg) is applied to a point midway between
pulleys. Refer to Figure 47.
d. After proper belt tension has been obtained,
tighten belt adjusting bolts firmly, then tighten
pivot bolts. Refer to Figure 47.