Specifications

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
23
70304601
Specific Conversion Procedures
How to Convert Gas Valve from Regulated to
Unregulated
NOTE: Conversion from regulated to unregulated
is only needed when regulated tumblers were
ordered, but regulated tumblers were needed.
Johnson GM7000 gas valve:
1. Disconnect electrical power from tumbler. Close
gas shut-off valve to tumbler. Refer to Figure 7.
2. Follow instructions in Conversion Kit, Part No.
431485 (Johnson Part No. GM-70 CBP).
NOTE: This kit does not contain any burner
orifices.
3. Change burner orifice size as required by the
appropriate table according to How to Change
Burner Orifice Size.
4. Commission tumbler for use.
Figure 7
TMB2135N
1 Gas Shut-Off Valve Assembly (closed position)
(Not Supplied)
6 Required Burner Orifice Pressure
7 Manometer
2 Gas Valve 8 Hose - Connect Over Loosened Slotted
Pressure Tap Screw in Bottom of Gas Valve
3 Burner Orifice
4 Regulator Adjusting Housing and Gasket
(Regulated version shown)
9 Spud Holder
10 Outlet Pressure Tap
5 Gas Valve Bracket
TMB2135N
1
2
3
4
7
9
10
8
6
5