Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
25. SPARK TO PILOT BURNER NO PILOT FLAME
(Electronic Pilot Ignition Models Only)
24 VOLTS BETWEEN
TERMINAL 1 AND
GROUND ON
ELECTRONIC
PACKAGE
YES
NO
GAS PRESENT AT
PILOT BURNER
(Disconnect white wire
from Terminal 3 and
light manually)
YES
REPLACE
ELECTRONIC
PACKAGE
REMOVE BLACK WIRE
FROM TERMINAL 1.
MOMENTARILY TOUCH TO
TERMINAL 2; IS CLICK
HEARD?
NO
REFER TO
NO SPARK TO
PILOT BURNER
CLEAR
OBSTRUCTION
PILOT FILTER,
TUBE OR
ORIFICE
OBSTRUCTED
YES
NO
YES
REPLACE RIGHT COIL
(PILOT OPERATOR)
NO
YES
YES
YES