Service manual
801681 67
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
b. Installation:
NOTE: Before removing protective backing from
new overlay, check fit of overlay to control panel
assembly. Refer to Figure 8.
(1) Once panel overlay is fitted to the front of
control panel frame, carefully peel
protective backing from the left end of
panel overlay and press into place.
(2) Remove rest of protective backing from
panel overlay and press overlay into place
on control panel frame.
(3) Reinstall all components into control panel.
(4) Following wiring diagram and reconnect
wires to components.
(5) Reinstall control panel.
Rear Control Washers (Electronic Control
Models)
IMPORTANT: Due to the sensitivity of the
electronic control, careful handling is required. As a
precautionary measure, we recommend using a
ground wrist strap when handling the electronic
control. Wrist strap, cord and alligator clip are
designed to carry away any electrostatic charge
from your body and to direct charge to an available
ground. By using this static protection device,
potential electrostatic discharge problems
associated with handling of electronic control will
be minimized. Always handle electronic control by
its metal edges. If a wrist strap is not available,
touch washer while it is plugged in before handling
control to dissipate any charge.
a. Removal:
(1) Remove control panel attaching screws.
Refer to Figure 7. Lay assembly forward
on protective pad on cabinet top. Refer to
Figure 7.
(2) Support control panel, press in on locking
tabs and unplug harness disconnect blocks
from backside of electronic control.
(3) Using a hair dryer or heat gun to warm the
overlay, remove control panel overlay by
peeling it from the control panel frame.
NOTE: Control panel overlay has an adhesive
backing.
b. Installation:
NOTE: Before removing protective backing from
new overlay, check fit of overlay to control panel
frame. Electronic control opening is the locating
guide.
(1) Once panel overlay is fitted to the front of
control panel frame, carefully peel
protective backing from the left end of
panel overlay and press into place.
(2) Remove rest of protective backing from
panel overlay and press overlay into place
on control panel assembly.
(3) While holding control by its metal edges,
place control in opening of control panel
and fasten control down with four screws.
Refer to Figure 11.
NOTE: For proper control alignment, tighten the
top two screws first then tighten the bottom screws.
Refer to Figure 11.
(4) Follow wiring diagram and reconnect wires
to control.
(5) Reinstall control panel.