Service manual
801681 51
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
• Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
Section 4
Grounding
23. WALL RECEPTACLE POLARITY CHECK
Refer to Figure 2.
Figure 2
H008GE3A
115 ± 12
V.A.C.
0
V.A.C.
115 ± 12
V.A.C.
Neutral
Side
Round
Grounding
Prong
Washer
Power Cord
L1
Ground
Neutral
NOTE: Have a
qualified electrician
check polarity of wall
receptacle. If a voltage
reading is measured
other than that
illustrated, the
qualified electrician
should correct the
problem.