Service manual

801681 105
Section 5 Service Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the washer before servicing.
Never start the washer with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
Motor not grounded! Disconnect electric power before servicing motor.
W485
WARNING
IMPORTANT: When installing pulley, always use a
new cap screw (included in kit) to prevent screw
from loosening during operation. Use a thread tap
to clean old Loctite out of pulley screw receiving
hole before installing new screw. This ensures that
inner basket and pulley properly seat.
e. Unscrew left hand thread screw half way.
f. Install pulley bolt tightening fixture between
the flat washer and the pulley. Refer to
Figure 43.
g. Tighten left hand thread screw until washer is
against pulley bolt tightening fixture.
h. Loosen screw about one half turn to free
fixture.
i. Remove pulley bolt tightening fixture.
j. From front of washer, pull inner basket forward
as far as possible. Flat washer should be against
pulley.
k. Push inner basket back into outer tub as far as
possible.
l. Tighten left hand thread screw. Be careful not
to push the trunnion shaft forward while
tightening the screw.
NOTE: Torque new left hand thread screw to 240
minimum to 260 maximum inch pounds (27.5 to
29.7 Nm).
Figure 41
FLW12K
Dial Indicator
Inner
Basket
Outer
Tub
Inner
Basket Lip