Service manual
32 803402
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electronic Control Troubleshooting
15. Pump or Drain Valve Does Not Operate
Is there
220-240 VAC
(or 120 VAC)*
across the
wht/blk and the white wire
going to the pump or
drain valve?
Is there
220-240 VAC
(or 120 VAC)*
across terminals
"H7-2" and
"H7-5?"
If the pump or
drain valve does not
operate check for
blockage. Replace
if necessary.
Correct wiring
between control
and pump or
drain valve.
Replace control
assembly.
(1)
(2)
No
Yes
No
Yes
FLW1784S
*Refer to machine serial plate for correct voltage.
NOTE: Check at beginning of spin/drain portion of cycle.