Alliance Products, LLC Murfreesboro, TN 37129 1-800-522-3973 OPERATIONS MANUAL DALPH1022 HEATED PELLET / PLATE DISPENSER Rev.
GENERAL INFORMATION ….………………………………… 3 RECEIVING INSPECTIONS ……………………………………. 3 INSTALLATION ………………………………………………….. 4 ELECTRICAL ………………………………………………….. 5 START-UP ……...………………………………………………….. 6 CLEANING …….………………………………………………….. 7 TROUBLESHOOTING…………………………………………… 8 PARTS LIST / DIAGRAMS …………………………………….. 9 PREVENTIVE MAINTENANCE ..……………………………… 13 WARRANTY …..…………………………………………………... 14 SERVICE AND ASSISTANCE…...……………………………….. 14 RETURN POLICY ………………………………………………….
GENERAL INFORMATION The Alliance Heated Pellet / Plate Dispensers is designed specifically for use with a wide variety of 9” plastic and stainless steel pellets and plates. Unit No. No. of Stacks Capacity per Stack Total Capacity DALPH1022 2 43 - 50 86 – 100 Overall Dimensions: Length Width Height 36" 23 3/4" 42 13/16" Electrical Requirements Voltage / Phase Amperage Cycle NEMA Plug Configuration 208V / 1 17.2 60 6-20P Shipping Weight (approx.) 285 lbs.
Alliance Damaged Goods Policy There are two types of damaged merchandise: A. Visible Damage B. Concealed Damage A. Visible Damage – The product being received is visibly damaged. 1. The receiver should refuse the damaged merchandise. 2. The receiver should sign the packing slip “refused merchandise due to damage” when receiving partial shipment. 3. Contact an Alliance customer service representative and alert them to the situation. B.
3 GENERAL INFORMATION The Alliance Heated Pellet / Plate Dispensers is designed specifically for use with a wide variety of 9” plastic and stainless steel pellets and plates. Unit No. No. of Stacks Capacity per Stack Total Capacity DALPH1022 2 43 - 50 86 – 100 Overall Dimensions: Length Width Height 36" 23 3/4" 42 13/16" Electrical Requirements Voltage / Phase Amperage Cycle NEMA Plug Configuration 208V / 1 17.2 60 6-20P Shipping Weight (approx.) 285 lbs.
4 Alliance Damaged Goods Policy There are two types of damaged merchandise: A. Visible Damage B. Concealed Damage A. Visible Damage – The product being received is visibly damaged. 1. The receiver should refuse the damaged merchandise. 2. The receiver should sign the packing slip “refused merchandise due to damage” when receiving partial shipment. 3. Contact an Alliance customer service representative and alert them to the situation. B.
2 GENERAL INFORMATION ….………………………………… 3 RECEIVING INSPECTIONS ……………………………………. 3 INSTALLATION ………………………………………………….. 4 ELECTRICAL ………………………………………………….. 5 START-UP ……...………………………………………………….. 6 CLEANING …….………………………………………………….. 7 TROUBLESHOOTING…………………………………………… 8 PARTS LIST / DIAGRAMS …………………………………….. 9 PREVENTIVE MAINTENANCE ..……………………………… 13 WARRANTY …..…………………………………………………... 14 SERVICE AND ASSISTANCE…...……………………………….. 14 RETURN POLICY ………………………………………………….
TROUBLESHOOTING CAUTION Thermostat adjustment should only be made only by qualified personnel. Complaint Problem A. Unit does not heat but fan operates. 1. Open high limit thermostat. 1A. Push reset button. 1B. Check for causes before restarting equipment. 1C. Replace hi-limit thermostat. 2. Loose wiring. 2. Check and secure wiring. 3. Defective heating element. 3. Replace heating element. B. Unit heats, but fan does not blow. 1. Defective motor. 1. Replace motor. 2. Jammed or loose fan blade. 2.
5 C. If a spring adjustment is required, proceed as follows. Lift elevating mechanism assembly up and out of the stainless steel cabinet. Set it on the floor. Disconnect but do not remove any unnecessary springs from the elevator carrier and replace mechanism back into the heater. D. See ELECTRICAL and START-UP sections before plugging unit into power supply.
DALPH1022 Exploded View Drawing
Dispenser Assembly Exploded View Drawing
7 CAUTION Operators should always wear gloves or use pellet / plate lifters when dispensing. After the unit is turned off, the pellets / plates remaining inside the unit will remain hot for some time. CLEANING CAUTION Make sure unit is unplugged and cool before attempting to clean. The following procedures should be followed during the regular cleaning routine on all of the pellet heaters. 1. Turn the unit off, disconnect the plug from the outlet, and allow the cabinet to cool.
6 WARNING Unit must not be run continually and must be turned off between meals. Otherwise, unit may shut off automatically requiring service reset. Warranty may be voided if used improperly. START-UP A. Overview These units are designed to heat plastic or stainless steel pellets or plates. The fan motor, heating element, and power indicator light will come on once the unit is turned on. Each well has a power indicator light to let the operator know the power is on.
WARRANTY One year on parts – 90 days on labor. Alliance provides to the original purchaser, only, a warranty for the DALPH1022. This warranty covers products and parts which prove to be defective in materials or workmanship within one (1) year of the date of shipment from the ALLIANCE factory. Repair or replacement will be at the option of ALLIANCE and will be f.o.b. the ALLIANCE factory. Warranty includes ninety (90) days for labor from date of shipment.
Return Policy No product may be returned to Alliance without Alliance’s prior written approval. Transportation charges are to be prepaid by the Buyer. Returned goods are subject to Alliance’s inspection and acceptance.