Datasheet

®
Parameter
Symbol
Test conditions
10
12
15
20
Unit
Min
Max
Min
Max
Min
Max
Min
Max
Input leakage
current
|I
LI
|
V
CC
=
Max
V
IN
= GND to
V
CC
1
1
1
1
µA
Output
leakage
current
|I
LO
|
V
CC
= Max
CE = V
IH
or OE =
V
IH
or WE =
V
IL
V
I/O
= GND to
V
CC
1
1
1
1
µA
Operating
power supply
current
I
CC
V = Max
V , f
CC
I = 0mA
Industrial
180
160
140
110
mA
Commercial
-
170
-
150
-
130
-
100
mA
CE
Standby power
supply current
I
SB
V
CC
= Max
CE V
IH
, f = Max
60
60
60
60
mA
I
SB1
V
CC
=
Max
CE V
CC
0.2V, V
IN
V
CC
0.2V
or
V
IN
0.2V, f =
0
8
8
8
8
mA
Output voltage
V
OL
I
OL
= 8 mA, V
CC
= Min
0.4
0.4
0.4
0.4
V
V
OH
I
OH
= 4 mA, V
CC
= Min
2.4
2.4
2.4
2.4
V
AS7C34098A
Recommended operating conditions
Parameter
Symbol
Min
Typical
Max
Unit
Supply voltage
V
CC
(10/12/15/20)
3.0
3.3
3.6
V
Input voltage
V
IH
**
2.0
V
CC
+ 0.5
V
V
IL
*
0.5
0.8
V
Ambient operating temperature
commercial
T
A
0
70
°C
industrial
T
A
40
85
°C
*
V
IL
min = 1.0V for pulse width less than 5ns.
*
V
IH
max = V
CC
+ 2.0V for pulse width less than 5ns.
DC operating characteristics (over the operating range)
1
IL
=
f
max
OUT
Capacitance (f = 1MHz, T
a
= 25° C, V
CC
= NOMINAL)
2
Parameter
Symbol
Signals
Test conditions
Max
Unit
Input capacitance
C
IN
A, CE, WE, OE, UB, LB
V
IN
=
0V
6
pF
I/O capacitance
C
I/O
I/O
V
IN
= V
OUT
= 0V
8
pF
11/14/11,v. 2.2 Alliance Memory Inc P. 3 of 11