Datasheet
NOTE 9: t
IS
and t
IH
(input setup and hold) derating
For all input signals the total t
IS
(setup time) and t
IH
(hold time) required is calculated by adding the data sheet t
IS(base)
and t
IH(base)
value to the Δt
IS
and Δ
tIH
derating value respectively.
Example: t
IS
(total setup time) = t
IS
(base) + Δt
IS
For slew rates in between the values listed in Tables 29, the derating values may obtained by linear interpolation.
These values are typically not subject to production test. They are verified by design and characterization
Table 29. Derating values for DDR2-800
△ tIS and △ tIH Derating Values for DR2-800
CK,CK# Differential Slew Rate
2.0 V/ns
1.5 V/ns
1.0 V/ns
△ tIS
△ tIH
△ tIS
△ tIH
△ tIS
△ tIH
Units
Notes
Command/
Address Slew rate
(V/ns)
4.0
+150
+94
+180
+124
+210
+154
ps
1
3.5
+143
+89
+173
+119
+203
+149
ps
1
3.0
+133
+83
+163
+113
+193
+143
ps
1
2.5
+120
+75
+150
+105
+180
+135
ps
1
2.0
+100
+45
+130
+75
+160
+105
ps
1
1.5
+67
+21
+97
+51
+127
+81
ps
1
1.0
0
0
+30
+30
+60
+60
ps
1
0.9
-5
-14
+25
+16
+55
+46
ps
1
0.8
-13
-31
+17
-1
+47
+29
ps
1
0.7
-22
-54
+8
-24
+38
+6
ps
1
0.6
-34
-83
-4
-53
+26
-23
ps
1
0.5
-60
-125
-30
-95
0
-65
ps
1
0.4
-100
-188
-70
-158
-40
-128
ps
1
0.3
-168
-292
-138
-262
-108
-232
ps
1
0.25
-200
-375
-170
-345
-140
-315
ps
1
0.2
-325
-500
-295
-470
-265
-440
ps
1
0.15
-517
-708
-487
-678
-457
-648
ps
1
0.1
-1000
-1125
-970
-1095
-940
-1065
ps
1
NOTE 10: The maximum limit for this parameter is not a device limit. The device will operate with a greater value
for this parameter, but system performance (bus turnaround) will degrade accordingly.
NOTE 11: MIN (t
CL
, t
CH
) refers to the smaller of the actual clock LOW time and the actual clock HIGH time as
provided to the device (i.e. this value can be greater than the minimum specification limits for t
CL
and t
CH
).
NOTE 12: t
QH
= t
HP
– t
QHS
, where:
t
HP
= minimum half clock period for any given cycle and is defined by clock HIGH or clock LOW (t
CH
, t
CL
).
t
QHS
accounts for:
1) The pulse duration distortion of on-chip clock circuits; and
2) The worst case push-out of DQS on one transition followed by the worst case pull-in of DQ on the next
transition, both of which are, separately, due to data pin skew and output pattern effects, and p-channel
to n-channel variation of the output drivers.
NOTE 13: t
DQSQ
: Consists of data pin skew and output pattern effects, and p-channel to n-channel variation of the
output drivers as well as output slew rate mismatch between DQS / DQS# and associated DQ in any
given cycle.
NOTE 14: t
DAL
= WR + RU{ t
RP
[ns] / t
CK
[ns] }, where RU stands for round up.WR refers to the t
WR
parameter stored
in the MRS. For t
RP
, if the result of the division is not already an integer, round up to the next highest
integer. t
CK
refers to the application clock period.
NOTE 15: The clock frequency is allowed to change during self–refresh mode or precharge power-down mode. In
case of clock frequency change during precharge power-down.
NOTE 16: ODT turn on time min is when the device leaves high impedance and ODT resistance begins to turn on.
ODT turn on time max is when the ODT resistance is fully on. Both are measured from t
AOND
, which is
interpreted differently per speed bin. For DDR2- 800, t
AOND
is 2 clock cycles after the clock edge that
registered a first ODT HIGH counting the actual input clock edges.
AS4C64M16D2A-25BIN
AS4C64M16D2A-25BCN
Confidential
- 31 of 62 -
Rev.1.1 October 2017