Datasheet
Table Of Contents
- DDR3L SDRAM
- Description
- State Diagram
- Functional Description
- Functional Block Diagrams
- Ball Assignments and Descriptions
- Package Dimensions
- Electrical Specifications
- Thermal Characteristics
- Electrical Specifications – I DD Specifications and Conditions
- Electrical Characteristics – 1.35V IDD Specifications
- Electrical Specifications – DC and AC
- ODT Characteristics
- Output Driver Impedance
- Output Characteristics and Operating Conditions
- Speed Bin Tables
- Electrical Characteristics and AC Operating Conditions
- Electrical Characteristics and AC Operating Conditions
- Command and Address Setup, Hold, and Derating
- Data Setup, Hold, and Derating
- Commands – Truth Tables
- Commands
- Input Clock Frequency Change
- Write Leveling
- Initialization
- Voltage Initialization / Change
- Mode Registers
- Mode Register 0 (MR0)
- Mode Register 1 (MR1)
- Mode Register 2 (MR2)
- Mode Register 3 (MR3)
- MODE REGISTER SET (MRS) Command
- ZQ CALIBRATION Operation
- ACTIVATE Operation
- READ Operation
- WRITE Operation
- PRECHARGE Operation
- SELF REFRESH Operation
- Extended Temperature Usage
- Power-Down Mode
- RESET Operation
- On-Die Termination (ODT)
- Dynamic ODT
- Synchronous ODT Mode
- Asynchronous ODT Mode
- Asynchronous to Synchronous ODT Mode Transition (Power-Down Exit)

Table 56: Electrical Characteristics and AC Operating Conditions for Speed Extensions (Continued)
Notes 1–8 apply to the entire table
Parameter Symbol
DDR3L-1866 DDR3L-2133
Unit NotesMin Max Min Max
ACTIVATE command to power-down entry
t
ACTPDEN MIN = 2 CK
PRECHARGE/PRECHARGE ALL command to
power-down entry
t
PRPDEN MIN = 2 CK
REFRESH command to power-down entry
t
REFPDEN MIN = 2 CK 37
MRS command to power-down entry
t
MRSPDEN MIN =
t
MOD (MIN) CK
READ/READ with auto precharge command
to power-down entry
t
RDPDEN MIN = RL + 4 + 1 CK
WRITE command to
power-down entry
BL8 (OTF, MRS)
BC4OTF
t
WRPDEN MIN = WL + 4 +
t
WR/
t
CK (AVG)
CK
BC4MRS
t
WRPDEN MIN = WL + 2 +
t
WR/
t
CK (AVG)
CK
WRITE with auto pre-
charge command to
power-down entry
BL8 (OTF, MRS)
BC4OTF
t
WRAP-
DEN
MIN = WL + 4 + WR + 1 CK
BC4MRS
t
WRAP-
DEN
MIN = WL + 2 + WR + 1 CK
Power-Down Exit Timing
DLL on, any valid command, or DLL off to
commands not requiring locked DLL
t
XP MIN = greater of 3CK or 6ns;
MAX = N/A
CK
Precharge power-down with DLL off to
commands requiring a locked DLL
t
XPDLL MIN = greater of 10CK or 24ns; MAX = N/A CK 28
ODT Timing
R
TT
synchronous turn-on delay ODTL on CWL + AL - 2CK CK 38
R
TT
synchronous turn-off delay ODTL off CWL + AL - 2CK CK 40
R
TT
turn-on from ODTL on reference
t
AON –195 195 –180 180 ps 23, 38
R
TT
turn-off from ODTL off reference
t
AOF 0.3 0.7 0.3 0.7 CK 39, 40
Asynchronous R
TT
turn-on delay
(power-down with DLL off)
t
AONPD MIN = 2; MAX = 8.5 ns 38
Asynchronous R
TT
turn-off delay
(power-down with DLL off)
t
AOFPD MIN = 2; MAX = 8.5 ns 40
ODT HIGH time with WRITE command and
BL8
ODTH8 MIN = 6; MAX = N/A CK
8Gb: x4, x8, x16 DDR3L SDRAM
Electrical Characteristics and AC Operating Conditions
88
Rev 2.0 June 2016
© 2015 Alliance Memory, Inc. All rights reserved.
Alliance Memory Inc. reserves the right to change products or specification without notice
Alliance Memory Inc. 511 Taylor Way, San Carlos, CA 94070
TEL: (650) 610-6800 FAX: (650) 620-9211