Datasheet

AS4C32M16D1A-C&I
15
Rev. 1.0 Mar. /2015
Read Burst Required CAS Latencies (CL=3)
DO
n
CK
CK
COMMAND
READ NOP NOP
NOP NOP NOP
Bank A,
Col n
ADDRESS
DQS
DQ
CL=3
Don’t Care
DO n=Data Out from column n
Burst Length=4
3 subsequent elements of Data Out appear in the programmed order
following DO n