Datasheet

Allowed time before ringback (tDVAC) for CK - CK and DQS - DQS
Single-ended requirements for differential signals
Each individual component of a differential signal (CK, DQS, CK
, DQS) has also to comply with certain
requirements for single-ended signals.
CK and CK
have to approximately reach VSEH min / VSEL max [ approximately equal to the AC-levels
( VIH(AC) / VIL(AC) ) for Address/command signals ] in every half-cycle.
DQS, DQS
have to reach VSEH min / VSEL max [ approximately the ac-levels ( VIH(AC) / VIL(AC) ) for DQ
signals ] in every half-cycle proceeding and following a valid transition.
Note that the applicable AC-levels for Address/command and DQ’s might be different per speed-bin etc.
E.g. if VIH150(AC) / VIL150(AC) is used for Address/command signals, then these AC-levels apply also for
the single-ended components of differential CK and CK
.
Slew Rate [V/ns]
tDVAC [ps] @ |VIH/Ldiff(AC)| = 350mV tDVAC [ps] @ |VIH/Ldiff(AC)| = 300mV
Min. Max. Min. Max.
> 4.0 75 - 175 -
4.0 57 - 170 -
3.0 50 - 167 -
2.0 38 - 163 -
1.8 34 - 162 -
1.6 29 - 161 -
1.4 22 - 159 -
1.2 13 - 155 -
1.0 0 - 150 -
< 1.0 0 - 150 -
AS4C256M16D3B-12BIN
AS4C256M16D3B-12BCN
Confidential
- 21/41 -
Rev.1.1 April 2017