Washer Extractors Technical specifications Installation instructions Maintenance Instruction manual WFF65, WFF75, WFF100 WFF135, WFF165 for corresponding “CWF” and “IWF” models, see page 5 for complete model list. Part No.
Contents 1 Model Numbers ............................................................................................... 5 2 Safety and Environmental Informations ....................................................... 8 Safety ........................................................................................................... 8 Environmental ............................................................................................... 9 Explanation of Safety Messages ...............................
5 Steam connection ......................................................................................... 43 6 Technical remarks ........................................................................................ 44 Internal connections of the electrical heating ............................................. 44 7 Maintenance instruction of the machine .................................................... 45 End of day ....................................................................................
1 Model Numbers Build-up xWF065yyMyyyyyy xWF075yyMyyyyyy xWF100yyMyyyyyy xWF135yyMyyyyyy xWF165yyMyyyyyy WFF65 WFF75 WFF100 WFF135 WFF165 xWF014yyMyyyyyy xWF018yyMyyyyyy xWF025yyMyyyyyy xWF030yyMyyyyyy xWF035yyMyyyyyy Model numbers IWF014ANM IWF018MLM IWF025SEM IWF014MNM IWF018MXM IWF025SRM IWF014MCM IWF018MYM IWF025SLM IWF014MDM IWF018SCM IWF025SXM IWF014MEM IWF018SDM IWF025SYM IWF014MLM IWF018SEM IWF030ANM IWF014MXM IWF018SRM IWF030MNM IWF014MYM IWF018SLM IWF030MCM IWF014SCM I
1 IWF065ANM IWF074ZNM IWF135SCM IWF065MNM IWF074ZCM IWF135SDM IWF065MCM IWF074ZDM IWF135SEM IWF065MDM IWF074ZEM IWF135SRM IWF065MEM IWF074ZLM IWF135SLM IWF065MLM IWF074ZXM IWF135SXM IWF065MXM IWF074ZYM IWF135SYM IWF065MYM IWF100ANM IWF135ZNM IWF065SCM IWF100MNM IWF135ZCM IWF065SDM IWF100MCM IWF135ZDM IWF065SEM IWF100MDM IWF135ZEM IWF065SRM IWF100MEM IWF135ZLM IWF065SLM IWF100MLM IWF135ZXM IWF065SXM IWF100MXM IWF135ZYM IWF065SYM IWF100MYM IWF165ANM IWF065ZNM IWF1
1 CWF014ANM CWF065MEM CWF014MNM CWF065MLM CWF014MCM CWF065MXM CWF014MDM CWF065MYM CWF014MEM CWF074ANM CWF014MLM CWF074MNM CWF014MXM CWF074MCM CWF014MYM CWF074MDM CWF018ANM CWF074MEM CWF018MNM CWF074MLM CWF018MCM CWF074MXM CWF018MDM CWF074MYM CWF018MEM CWF100ANM CWF018MLM CWF100MNM CWF018MXM CWF100MCM CWF018MYM CWF100MDM CWF025ANM CWF100MEM CWF025MNM CWF100MLM CWF025MCM CWF100MXM CWF025MDM CWF100MYM CWF025MEM CWF135ANM CWF025MLM CWF135MNM CWF025MXM CWF135MCM CWF0
2 Safety and Environmental Informations Safety CAUTION LABELS Please familiarize yourself with the following standard warning symbols. They are used throughout this manual and on the equipment to alert you to possible hazards. Anyone operating or servicing this equipment must understand these symbols and must follow all safety rules in this manual. ELECTRICAL HAZARD This symbol alerts you to the presence of a dangerous voltage, which could cause a serious shock resulting in personal injury or death.
2 Environmental Disposal of Unit This appliance is marked according to the European directive 2002/96/ EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
2 Explanation of Safety Messages Throughout this manual and on machine decals, you will find precautionary statements (“DANGER,” “WARNING,” and “CAUTION”) followed by specific instructions. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
2 Important Safety Instructions WARNING To reduce the risk of fire, electric shock, serious injury or death to persons when using your washer, follow these basic precautions: 1. Read all instructions before using the washer. 2. Refer to the GROUNDING INSTRUCTIONS in the installation Manual for the proper grounding of the washer. 3.
2 21. Loading door MUST BE CLOSED any time the washer is to fill, tumble, or spin. DO NOT bypass the loading door switch by permitting the washer to operate with the loading door open. 22. Always read and follow manufacturer’s instructions on packages of laundry and cleaning aids. Heed all warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times (preferably in a locked cabinet). 23.
2 Operator Safety WARNING NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury. To ensure the safety of machine operators, the following maintenance checks must be performed daily: 1. Prior to operating the machine, verify that all warning signs are present and legible. Missing or illegible signs must be replaced immediately. Make certain that spares are available. 2. Check door interlock before starting operation of the machine: a.
3 Technical data and dimensions Technical data WFF65, IWF065, IWF014, CWF065, CWF014 METRIC US 1:11 5,9 kg 13 lb. 1:10 6,5 kg 14.33 lb. 1:9 7,2 kg 15.87 lb. Diameter 530 mm 20.86 inch Depth Capacity (dry weight) Ratio [kg/Lit] Cylinder 295 mm 11.61 inch Volume 65 Lit 2.29 ft³ Height 1041 mm 40.98 inch Width 660 mm 25.98 inch Depth 797 mm 31.37 inch Diameter door opening 300 mm 11.81 inch Door height 355 mm 13.
3 Dimensions WFF65, IWF065, IWF014, CWF065, CWF014 Legend: metric mm [inches] 355 [13.98] 1041 [40.98] 1014 [39.92] 220 [8.66] 5 [0.2] 55 [2.17] 550 [21.65] 55 [2.17] 37 [1.46] 273 [10.75] 69 [2.72] 660 [25.98] 287 [11.3] 48 [1.89] 670 [26.37] 728 [28.66] 226 [8.9] 151 [5.94] 75 [2.95] A D F B C E G I 696.5 [27.42] 747 [29.41] L 277.5 [10.92] K 180 [7.09] 164.5 [6.48] 660 [25.98] A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D.
3 Technical data WFF75, IWF074, IWF018, CWF074, CWF018 METRIC US 1:11 6,9 kg 14.33 lb. 1:10 7,3 kg 16.09 lb. 1:9 8,4 kg 18.51 lb Diameter 530 mm 20.86 inch Depth 345 mm 13.58 inch Volume 73 Lit 2.57 ft³ Height 1041 mm 40.98 inch Width 660 mm 25.98 inch Depth 797 mm 31.37 inch Diameter door opening 300 mm 11.81 inch Door height 355 mm 13.
3 Dimensions WFF75, IWF074, IWF018, CWF074, CWF018 220 [8.66] 355 [13.98] 1014 [39.92] 1041 [40.98] Legend: metric mm [inches] 5 [0.2] 55 [2.17] 550 [21.65] 55 [2.17] 37 [1.46] 233 [9.17] 69 [2.72] 660 [25.98] 327 [12.87] 48 [1.89] 670 [26.37] 728 [28.66] 226 [8.9] 151 [5.94] 75 [2.95] A D F B C E G I 696.5 [27.42] 747 [29.41] L 277.5 [10.92] A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E.
3 Technical data WFF100, IWF100, IWF025, CWF100, CWF025 METRIC US 1:11 8,6 kg 18.95 lb. 1:10 9,5 kg 20.94 lb. 1:9 10,5 kg 23.14 lb. Diameter 530 mm 20.86 inch Depth Capacity (dry weight) Ratio [kg/Lit] Cylinder 440 mm 17.32 inch Volume 95 Lit 3.35 ft³ Height 1041 mm 40.98 inch Width 660 mm 25.98 inch Depth 897 mm 35.31 inch Diameter door opening 300 mm 11.81 inch Door height 355 mm 13.
3 Dimensions WFF100, IWF100, IWF025, CWF100, CWF025 220 [8.66] 355 [13.98] 1014 [39.92] 1041 [40.98] Legend: metric mm [inches] 5 [0.2] 55 [2.17] 550 [21.65] 55 [2.17] 660 [25.98] 37 [1.46] 233 [9.17] 69 [2.72] 427 [16.81] 48 [1.89] 770 [30.31] 828 [32.6] 226 [8.9] 151 [5.94] 75 [2.95] A D F B C E G I 696.5 [27.42] 747 [29.41] L 277.5 [10.92] A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E.
3 Technical data WFF135, IWF135, IWF030, CWF135, CWF030 METRIC US 1:11 12 kg 26.45 lb. 1:10 13,2 kg 29.10 lb. 1:9 14,5 kg 31.96 lb. Diameter 650 mm 25.59 inch Depth Capacity (dry weight) Ratio [kg/Lit] Cylinder 400 mm 17.74 inch Volume 132 Lit 4.66 ft³ Height 1204 mm 47.40 inch Width 780 mm 30.70 inch Depth 842 mm 33.14 inch Diameter door opening 300 mm 11.81 inch Door height 455 mm 17.91 inch To center 606 mm 23.
3 Dimensions WFF135, IWF135, IWF030, CWF135, CWF030 Legend: metric mm [inches] 220 [8.66] 455 [17.91] 1175 [46.26] 1204 [47.4] 84 [3.31] 70 [2.76] 640 [25.2] 70 [2.76] 28 [1.1] 260 [10.24] 410 [16.14] 33 [1.3] 760 [29.92] 780 [30.71] 82 [3.23] 816 [32.12] 332 [13.07] 267 [10.51] 202 [7.95] 106.5 [4.19] A F D B C E G I 843 [33.19] 894 [35.2] A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E.
3 Technical data WFF165, IWF165, CWF165 METRIC US 1:11 15 kg 33.06 lb. 1:10 16,5 kg 36.37 lb. 1:9 18,3 kg 40.34 lb. Diameter 650 mm 25.59 inch Depth 500 mm 19.68 inch Volume 165 Lit 5.83 ft³ Height 1204 mm 47.40 inch Width 780 mm 30.70 inch Depth 942 mm 37.08 inch Diameter door opening 300 mm 11.81 inch Door height 455 mm 17.91 inch To center 606 mm 23.
3 Dimensions WFF165, IWF165, CWF165 Legend: metric mm [inches] 220 [8.66] 455 [17.91] 1175 [46.26] 1204 [47.4] 84 [3.31] 70 [2.76] 640 [25.2] 70 [2.76] 28 [1.1] 260 [10.24] 510 [20.08] 33 [1.3] 860.1 [33.86] 780 [30.71] 82 [3.23] 916.1 [36.07] 332 [13.07] 267 [10.51] 202 [7.95] 106.5 [4.19] A F D B C E G I 843 [33.19] 894 [35.2] A. Ventilation soap dispenser B. Liquid soap connetions C. Hard water connections 3/4" D. Warm water connections 3/4" E. Soft water connections 3/4" F.
4 Installation and Connection Instructions CAUTION Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked. Surface The machine must be securely fixed on a flat surface (metal base, concrete or solid ground). The anchoring is to be done on the 6 provided places (A) (See Label 1) in the holes on the corner of the base.
4 Mounting Bolt Hole Locations for machines, WFF65, IWF065, IWF014, CWF065, CWF014 37 [1.46] Legend: metric mm [inches] Ø 22 645 [25.4] 48 [1.89] 287 [11.3] 560 [22.05] ] 273 [10.75] 87 0. [Ø 55 [2.17] 550 [21.65] 55 [2.17] 660 [25.
4 Mounting Bolt Hole Locations for machines, WFF75, IWF074, IWF018, CWF074, CWF018 37 [1.46] Legend: metric mm [inches] Ø 645.1 [25.4] 48 [1.89] 327 [12.87] 560 [22.05] ] 87 0. [Ø 233 [9.17] 22 55 [2.17] 550 [21.65] 55 [2.17] 660 [25.
4 Mounting Bolt Hole Locations for machines, WFF100, IWF100, IWF025, CWF100, CWF025 37 [1.46] Legend: metric mm [inches] Ø 745 [29.33] 48 [1.89] 427 [16.81] 660 [25.99] ] 87 0. [Ø 233 [9.17] 22 55 [2.17] 550 [21.65] 55 [2.17] 660 [25.
4 Mounting Bolt Hole Locations for machines, WFF135, IWF135, IWF030, CWF135, CWF030 28 [1.1] Legend: metric mm [inches] Ø 33 [1.3] 410 [16.14] 640 [25.2] 70 [2.76] 780 [30.71] 28 731 [28.78] 670 [26.38] ] 87 0. [Ø 260 [10.24] 22 70 [2.
4 Mounting Bolt Hole Locations for machines, WFF165, IWF165, CWF165 28 [1.1] Legend: metric mm [inches] Ø 33 [1.3] 510 [20.08] 831 [32.72] 770 [30.31] ] 87 0. [Ø 260 [10.24] 22 70 [2.76] 640 [25.2] 70 [2.76] 780 [30.
4 Water connection The machine is delivered with hoses with 3/4" connections. These hoses fit the water inlet valves of the machine and the main water inlet taps. All the inlet valves have to be connected. To ensure the optimal functioning of the water inlet valves, the water pressure on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the cycle time will increase considerably. International inlet flow capacity per minute (gallons / liters): 4.23 / 16.
4 Electrical Installation Important Electrical ratings are subject to changes. Refer to serial plate decal for electrical ratings information specific to your machine. WARNING Hazardous Voltage. Can cause shock, burn or cause death. Allow machine power to remain off for two minutes prior to working in and around AC inverter drive. WARNING Hazardous Voltage. Can cause shock, burn or death.
4 The connection should be shielded in a liquid tight or approved flexible conduit with proper conductors of correct size installed in accordance with the National Electric Code or other applicable codes. The connection must be made by a qualified electrician using the wiring diagram provided with the washer-extractor, or according to accepted European standards for CE-approved equipment. Use wire sizes indicated in Table 2 through 7 for runs up to 50 feet. Use next larger size for runs of 50 to 100 feet.
4 Main power connection Label 4 Connection label: Machine power connections are made at the back of the machine. Three or four conductor power cable is the recommended method (See chapter electrical specs for minimum cable requirements, if local electrical codes exceed these requirements, follow local codes). The number of conductors in this cable and the proper connection points for the cable wires shall be determined by the machine and power requirements.
4 200-240 Volts, 3-Phase, 3-wire + PE, 50 or 60 Hertz Configuration (Named: Q-Voltage or 3-phase X-Voltage): With supply power of: 200-240 Volts, 3-phase, 3-wire, after connecting the green/yellow PE ground wire, connect one power wire to each of the terminals at the bottom of the power contactor switch marked: “L1,L2,L3”.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications WFF65, IWF065, IWF014, CWF065, CWF014 65 liters / 14 pounds Boiler Fed/Steam Heat 3 10 10 14/2.5 P 380-415 50/60 3 3+N+PE 7 15 16 14/2.5 Q 200-240 50/60 3 3+PE 7 15 16 14/2.5 X 200-240 50/60 1/3 2/3+PE 7 15 16 14/2.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications WFF75, IWF074, IWF018, CWF074, CWF018 75 liters / 18 pounds Boiler Fed/Steam Heat 3 10 10 14/2.5 P 380-415 50/60 3 3+N+PE 7 15 16 14/2.5 Q 200-240 50/60 3 3+PE 7 15 16 14/2.5 X 200-240 50/60 1/3 2/3+PE 7 15 16 14/2.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment.
4 WARNING The washer-extractor should be connected to an individual branch circuit not shared with lighting or other equipment. Electrical Specifications WFF165, IWF165, CWF165 165 liters / 35 pounds Boiler Fed/Steam Heat 4 10 10 14/2.5 P 380-415 50/60 3 3+N+PE 12 15 16 14/2.5 Q 200-240 50/60 3 3+PE 12 15 16 14/2.5 X 200-240 50/60 1/3 2/3+PE 12 15 16 14/2.
4 Liquid soap connection (option) Connection of the liquid soap hoses The liquid soap connection consists of 8 connections for liquid soap (See Label 5). The central opening is used for ventilation. WARNING Label 5 Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals.
4 The 220V can be transformed to other values to drive other type soap pumps. Example: pumps 24V ~. (See Label 7) Label 7 Also, pumps with different operating tension can be combined. Example: 5 pumps 220V ~ and 1 pump 24V ~.
4 Connection of a central operating panel for coin machines (option) WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. At the backside above the main connectors, you find a printboard, to which the central operating panel for coin machines can be connected.
5 Steam connection WARNING Never touch internal or external steam pipes, connections, or components. These surfaces can be extremely hot and will cause severe burns. The steam must be turned off and the pipe, connections, and components allowed to cool before the pipe can be touched. Machines with steam heating must have a steam valve between the steam installation and the machine. 5 3 4 3 2 1 6 7 With direct steam injection into the machine (See Table 7) 1. Steam pipe 2. Steam cut-off valve 3.
6 Technical remarks Internal connections of the electrical heating 1 AC Heating R5 3kw LC1D0901 Table 8 3 AC Heating 3x230V R5 3x400V R5 4,2kw 3x1,4kw See label 14 LC1D0901 See label 15 LC1D0901 6kw 3x2kw See label 14 LC1D0901 See label 15 LC1D0901 9kw 3x3kw See label 14 LC1D1810 See label 15 LC1D0901 12kw 3x4kw -------- -------- See label 14 LC1D0901 12kw 3x2kw 3x2kw See label 14 See label 14 LC1D1810 LC1D1810 See label 15 LC1D0901 15kw 3x2kw 3x2kw See label 14 Se
7 Maintenance instruction of the machine WARNING To reduce the risk of electric shock, disconnect this appliance from the power supply before attempting any user maintenance. Turning the controls to the OFF position does not disconnect this appliance from the power supply. Before starting wiring or inspection, power must be switched OFF, check to make sure that the operation panel indicator is off.
7 Annual maintenance Belt tension: Verify that the belts are running in the middle of the basket pulley. Verify the belt tension according to the table below. Belt tension measurements should be taken as close as possible to the center of the belt span (see figure).
8 Contact Information Nameplate Nameplate Location The nameplate is located at the rear of the machine. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance. See labels 16 and 17.
8 Position of the Serialplate Replacement Parts If literature or replacement parts are required, contact the source from which the machine was purchased or contact the phone numbers or websites shown on the nameplate.
9 Repair and after-sales service In case of important malfunctions and deficiencies, which you cannot resolve yourself, contact your distributor. Distributor : Name:..................................................................................... Address:................................................................................. Tel.:......................................................................................... Machine : Type:.......................................................