Cabinet Hardmount Operating Instructions CHM1772C Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com Part No.
Basic Installation/Operation Table of Contents Safety Information.............................................................................. Important Safety Instructions ............................................................... Safety Decals ........................................................................................ Operator Safety..................................................................................... 2 2 4 5 Specifications and Dimensions.............................
Basic Installation/Operation Safety Information Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. DANGER DANGER indicates the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the danger is ignored.
Basic Installation/Operation 9. Do not install or store the washer where it will be exposed to water and/or weather. 10. Do not tamper with the controls. 11. Do not repair or replace any part of the washer, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that the user understands and has the skills to carry out. 12.
Basic Installation/Operation WARNING CAUTION This machine must be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of this type of machinery. They must also be familiar with the potential hazards involved. Failure to observe this warning may result in personal injury and/or equipment damage, and may void the warranty. SW004 IMPORTANT: Ensure that the recommended clearances for inspection and maintenance are provided.
Basic Installation/Operation Operator Safety Do not bypass any safety devices in the machine. WARNING WARNING NEVER insert hands or objects into basket until it has completely stopped. Doing so could result in serious injury. SW012 To ensure the safety of machine operators, the following maintenance checks must be performed daily: Never operate the machine with a bypassed or disconnected balance system.
Basic Installation/Operation Specifications and Dimensions 2 Speed Models Specification 20 30 40 60 Net weight, lbs. (kg) 387 (176) 489 (222) 692 (314) 812 (368) Domestic shipping weight, lbs. (kg) 420 (191) 530 (240) 734 (333) 854 (387) Domestic shipping volume, ft3 (m3) 30.5 (0.86) 40.75 (1.15) 50 (1.42) 64 (1.81) Export shipping weight lbs., (kg) 475 (215) 593 (269) 816 (370) 948 (430) Export shipping volume, ft3 (m3) 36.2 (1.03) 49.9 (1.41) 60 (1.70) 75.8 (2.
Basic Installation/Operation Table 1 (Continued) 2 Speed Models (Continued) Specification 20 30 40 60 1 1 1 1 Wash/reverse power, HP (kW) 0.15 (0.11) 0.24 (0.18) 0.40 (0.30) 0.55 (0.41) High extract power, HP (kW) .74 (0.55) 1.34 (1.00) 1.8 (1.3) 2.7 (2.01) Wash/reverse speed, RPM 57 49 51 44 High extract speed, RPM 528 464 491 469 Wash/reverse centrifugal force, Gs 0.9 0.8 0.8 0.9 High extract centrifugal force, Gs 80.3 72.1 78.1 85.4 Steam inlet connection size, in.
Basic Installation/Operation Variable-Speed and Fixed-Speed Models Specification 20 30 40 60 80 125 Net weight, lbs. (kg) 386 (175) 498 (226) 706 (321) 773 (350) 1374 (623) 2301 (1044) Domestic shipping weight, lbs. (kg) 424 (191) 545 (245) 744 (338) 824 (373) 1461 (663) 2384 (1081) Domestic shipping volume, ft3 (m3) 27 (0.76) 34.4 (0.98) 43.6 (1.24) 52.2 (1.48) 102.2 (2.89) 163 (4.3) Export shipping weight, lbs.
Basic Installation/Operation Table 2 (Continued) Variable-Speed and Fixed-Speed Models (Continued) Specification 20 30 40 60 80 125 Gentle wash/reverse speed, RPM 29 27 26 26 22 26 Wash/reverse speed, RPM 52 52 46 43 40 37 Distribution speed, RPM 92 92 82 77 70 65 Low extract speed, RPM 366 366 328 307 280 260 Medium extract speed, RPM (Not available on Electronic Control models.
Basic Installation/Operation Dimensional Clearances C FRONT A B CHM2280N CHM2280N Figure 1 Machine Capacity Dimensional Clearances Dimensions 20 30 40 60 80 125 A 2 in. (51 mm) 2 in. (51 mm) 2 in. (51 mm) 2 in. (51 mm) 6 in. (152 mm) 24 in. (600 mm) B .5 in. (12.5 mm) .5 in. (12.5 mm) .5 in. (12.5 mm) .5 in. (12.5 mm) .5 in. (12.5 mm) .5 in. (12.5 mm) C (recommended) 24 in. (610 mm) 24 in. (610 mm) 24 in. (610 mm) 24 in. (610 mm) 24 in. (610 mm) 36 in.
Basic Installation/Operation Dimensions 20, 30, 40, 60 and 80 Pound Models H G 2 4 3 F 1 5 P R C Q A B L M N D E 6 I O K J 20, 30, 40, 60 AND 80 POUND CAPACITY MACHINES CHM2278N CHM2278N 1 2 3 Supply Dispenser Input Power Block Hot Water Inlet 4 5 6 Cold Water Inlet Vacuum Breaker Drain Outlet Figure 2 F8321401 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11
Basic Installation/Operation Machine Capacity Dimensions Dimensions 20 30 40 60 80 A 35.15 in. (893 m) 38.03 in. (966 mm) 40.31 in. (1024 mm) 43.31 in. (1100 mm) 51.87 in. (1317 mm) B 34.52 in. (877 mm) 37.46 in. (951 mm) 39.71 in. (1009 mm) 42.4 in. (1077 mm) 48.68 in. (1236 mm) C 1.81 in. (46 mm) 1.73 in. (44 mm) 2.97 in. (75 mm) 2.42 in. (61 mm) 2.71 in. (69 mm) D 4.5 in. (114 mm) 4.5 in. (114 mm) 4.81 in. (122 mm) 4.69 in. (119 mm) 5.71 in. (145 mm) Standard 5.88 in.
Basic Installation/Operation 125 Model F 4 E D 2 5 6 7 8 P 1 3 Q H A G L M B C N I 9 O J K 125 POUND CAPACITY MACHINES CHM2279N CHM2279N 1 2 3 4 5 Dry Chemical Dispenser (Optional) Input Power Block Fans Valve Panel Cold Water Inlet 6 7 8 9 Hot Water Inlet Liquid Chemical Inlet Steam Inlet (Optional) Drain Outlet Figure 3 Machine Capacity Dimensions for 125 Pound Models A 78.8 in. (2002 mm) J 61.28 in. (1557 mm) B 14.62 in. (371 mm) K 70.81 in. (1799 mm) C 6.27 in.
Basic Installation/Operation Electrical Specifications Electrical Specifications 20 Pound Capacity Models Voltage Designation Standard Electric Heat AWG mm2 Circuit Breaker Full Load Amps mm2 AWG Circuit Breaker Full Load Amps Wire Phase Cycle Voltage Code 14 2.5 10 6.0 10 6.0 2 Speed Models B 120 60 1 2 16 20 12 4.0 N/A C 380 – 415 50 3 4 4 15 14 2.5 F 440 – 480 60 3 3 4 15 14 2.5 N/A J 200 50 3 3 5 15 14 2.
Basic Installation/Operation Electrical Specifications 40 Pound Capacity Models Voltage Designation Standard Electric Heat Full Load Amps Circuit Breaker AWG mm2 15 14 2.5 27 30 10 6.0 F 440 – 480 60 3 3 5 15 14 2.5 24 30 10 6.0 J 200 50 3 3 7 20 12 4.0 O 208 – 240 60 3 3 7 20 12 4.0 8 10.0 Y 208 – 240 60 1 2 14 30 10 6.
Basic Installation/Operation Electrical Specifications 80 Pound Capacity Models Voltage Designation Standard Electric Heat mm2 Full Load Amps Circuit Breaker AWG mm2 14 2.5 40 50 8 10.0 Q 200 – 240 50/60 3 3 11 15 14 2.5 82 90 3 25.0 X 200 – 240 50/60 1/3 2/3 16/11 20/15 12/14 4.0/2.
Basic Installation/Operation Operation NOTE: Available settings vary by model.
Basic Installation/Operation Operating Instructions, Vend Models Only 4. Close door and turn handle counter clockwise. Refer to Figure 6. 1. Turn on main power source (circuit breaker). 2. Turn handle clockwise to open. Refer to Figure 4. CHM2244N Figure 6 5. The default wash cycle will display. CHM2243N CHM2243N Figure 4 3. Load to capacity whenever possible. DO NOT OVERLOAD. Refer to Figure 5. NOTE: Underloading can cause out-of-balance conditions that can shorten machine life.
Basic Installation/Operation b. Bleach: • Liquid - Compartment 3 • Powder - Compartment 2 7. Add liquid and/or powder supplies to supply dispenser. Refer to Figure 7. a. Detergent: • Liquid - Compartment 1 (prewash) + Compartment 3 • Powder - Compartment 1 (prewash) + Compartment 2 c. Softener: • Liquid - Compartment 4 a. DETERGENT Powder Liquid CHM2227N CHM2228N b. BLEACH Liquid Powder CHM2230N CHM2229N c. SOFTENER CHM2231N Figure 7 8. Insert coin(s) or card as necessary.
Basic Installation/Operation Operating Instructions, OPL Models Only 1. Turn on main power source (circuit breaker). 4. Close door and turn handle counter clockwise. Refer to Figure 9. NOTE: For 125 models, close door and turn handle clockwise. 2. Turn door handle clockwise to open. NOTE: For 125 models, press the Unlock/Stop keypad. Turn door handle counter clockwise to open. 3. Load to capacity whenever possible. DO NOT OVERLOAD. Refer to Figure 8.
Basic Installation/Operation b. Bleach: 7. Add liquid and/or powder supplies to supply dispenser. Refer to Figure 10. • Liquid - Compartment 3 • Powder - Compartment 2 a. Detergent: • Liquid - Compartment 1 (prewash) + Compartment 3 • Powder - Compartment 1 (prewash) + Compartment 2 c. Softener: • Liquid - Compartment 4 a. DETERGENT Powder Liquid CHM2227N CHM2228N b. BLEACH Liquid Powder CHM2230N CHM2229N c. SOFTENER CHM2231N Figure 10 8. Press the START keypad. 10.
Basic Installation/Operation Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 11. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.