Specifications

Installation
33
F232086
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Control Function Test
The washer-extractor should be cleaned after the
installation is complete. A function test should then be
executed on the unloaded machine:
1. Check the power supply for such characteristics
as correct voltage, phase, and cycles to be certain
they are correct for the washer-extractor.
2. Open manual shut-off valves to the washer-
extractor.
NOTE: If the washer-extractor is equipped with
the WE-6 microcomputer, press the Emergency
Stop button at this point in the procedure.
3. Apply power to the washer-extractor.
NOTE: If the washer-extractor is equipped with
the WE-6 microcomputer, release the Emergency
Stop button at this point in the procedure by
pulling the button sharply.
4. Check the door interlock before starting
operation:
a. Attempt to start the washer with the door
open. The washer should not start with the
door open.
b. Close the door without locking it and attempt
to start the washer. The washer should not
start with the door unlocked.
c. Close and lock the door and start a cycle.
Attempt to open the door while the cycle is in
progress. The door should not open.
If the door lock and interlock are not functioning
properly, call a service technician.
5. Run a full test cycle:
a. For washer-extractors equipped with the WE-
6 microcomputer, select Cycle 01 by pressing
key 0 and key 1 on the keypad. Then press the
Start key.
Run the complete cycle, checking operation
of all functions.
b. For washer-extractors equipped with the S-
series microcomputer, select an appropriate
cycle from the 12 cycles listed in the S-series
Operation/Programming manual F232087.
Run the complete cycle, checking operation
of all functions.
As an alternative, a test cycle is available for
the S-series microcomputer. To access the test
cycle, verify that the RUN/PROGRAM mode
toggle switch is in the RUN position. Press
the Up or Down key until the display
alternately flashes “CHEC” and “CYC,
indicating that the test cycle is selected. Press
the Start key to begin the test cycle.
NOTE: Pressing the Start key while the test cycle is
in progress will prompt the computer to advance to
the next step in the test cycle. Drain steps may not
be skipped.
6. Cylinder rotation must be clockwise in the
extract step. If rotation is not clockwise in the
extract step, disconnect power. A qualified
electrician must reverse any two leads between
the mains contactor and the motor.