Specifications
Installation
F232086
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 16
Table 9
Connecting External Liquid Supplies
to the Washer-Extractor
1. Remove plugs from base. See Figure 16. Plugs
are assembled inside the tubing ring.
2. Install strain reliefs, included in the seal nut.
3. Insert tubes through base. Do not remove cups.
Tube should extend into the plastic cup, with the
exception of the softener tube, which should be
routed to the outside of the cup.
4. Tighten the seal nut to prevent tubing from
escaping the assembly.
The UW 3-speed washer-extractor has a
polypropylene supply dispenser with five supply
compartments. See Figure 17.
Do not attempt to make chemical injection electrical
connections to points other than those provided
specifically for that purpose by the factory.
PHM673N
1 Tubing from Pump
2 Seal Nut
3 Tubing Ring
4 Base
5 Lid
6 Nut
Chemical Injection Supply System
Number of dry supply compartments 5
Number of liquid supply connections 5
Liquid supply connection size, in (mm) 5/8 (15.9)
PHM673N
1
2
3
5
6
4