Specifications
Installation
29
F232086
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Chemical Injection Supply System
Undiluted chemical dripping can damage the washer-
extractor. Therefore, all chemical supply dispenser
pumps should be mounted below the washer’s
injection point. All dispenser tubing should also run
below the injection point. Loops do not prevent drips
if these instructions are not followed. Failure to follow
these instructions could damage the machine and void
the warranty. Figure 15 shows a typical Chemical
Injection Supply System.
Figure 15
Wear eye and hand protection when
handling chemicals; always avoid direct
contact with raw chemicals. Read the
manufacturer’s directions for accidental
contact before handling chemicals.
Ensure an eye-rinse facility and an
emergency shower are within easy reach.
Check at regular intervals for chemical
leaks.
SW016
WARNING
PHM672N
1 Injection Point 3 PVC Pipe
2 Chemical Dispenser Pump Outlet
PHM672N
1
3
2