Installation manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Diagnostic
F8138801
52
Alarms
The Alarms Menu contains three screens of
information. On the first screen, Alarms (1 of 3), the
eight most recent alarms will contain Cycle Number,
Segment Number, Step, Alarm Type, and the Date/
Time of the Alarm.
The second screen, Alarms (2 of 3), alarm counts list 1
through 8. Alarm counts consist of how many times a
specific alarm has occurred.
The third screen, Alarms (3 of 3), this is a continuation
of the alarm counts 9 through 14.
Press the or keypad to navigate to the
different screens in the Alarms Menu. Press the
keypad to go from screen 1 to screen 3. The actual
menus are informational only and cannot be navigated.
Press the keypad to return to display to
Diagnostic Menu or the Run Diagnostic Menu.
PHM1060R
Figure 63
PHM1061R
Figure 64
PHM1062R
Figure 65
Alarms (1 of 3)
ALARM COUNTS
C01: S02 Fill Error 08/01 01:37
C15: S01 Door Lock Error 07/20 04:37
C10: S10 Frame Balance Error 06/15 14:37
C00: S00 00/00 00:00
C00: S00 00/00 00:00
C00: S00 00/00 00:00
C00: S00 00/00 00:00
C00: S00 00/00 00:00
Alarms (2 of 3)
ALARM COUNTS
Lock Count: 1
Door Count: 0
Drain Count: 0
Drive Balance Switch Count: 0
Drive Fault Count: 0
Fill Count: 1
Frame Balance Count: 1
Open Count: 0
Alarms (3 of 3)
ALARM COUNTS
Rotation Count: 0
Short Count: 0
SPI Count: 0
Unbalance Count: 0
Heat Count: 0
Level Count: 0
IR Count: 1
Network Count: 1