Installation manual

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Global Setup
F8138801
42
Rapid Advance Menu
The Rapid Advance Menu has the option of whether
the user will be able to rapid advance through steps
while the machine is operating. Press the
or keypad to change the selection. All the
keypads have the same effect and will toggle the
selection between on or off. Press the or
keypad to jump to the Save Changes Menu. Use
or to move highlighted box to “Yes” or “No”.
Press keypad to return to Global Setup Menu. If
no changes were made, press the or
keypad to return to Global Setup Menu.
If the Rapid Advance Option is enabled (refer to
Global Setup, Rapid Advance section), the user can
advance a running machine cycle with presses of
the keypad. When the keypad is pressed,
the control will immediately show the next cycle step
in the Run Menu but will not change the outputs for a
period of at least five (5) seconds. The user may
advance into any cycle step except the Spray Rinse
Extract and Extract Steps. If the control is executing a
Drain step and the user presses to execute a
Rapid Advance, the control will skip over the Extract
Step. When the cycle is completed, the audit counter,
Total Rapid Advance Cycles is incremented rather
than the Total Machine Cycles audit counter. In
addition this cycle is recorded in the audit list “Last 25
Machine Cycles Completed” and the audit list “Last
10 Machine Cycles Rapid Advanced/Aborted.” Refer
to UniLinc PC and PDA Application User
Instructions for additional information on using a
PDA.
In the Run Menu, the total remaining cycle time is
reduced by the corresponding advance step time if
programmed. If the Rapid Advance Option is disabled
preventing a manual Rapid Advance, the user may still
execute a Rapid Advance using the PDA.
Shakeout Menu
The Shakeout Menu is used to set the Shakeout time
after the Extract Step. The and keypads
adjust the time. The time can be set from 0-120
seconds in increments of 20 seconds.
Press the or keypad to enter the Save
Changes Menu. Press or to move
highlighted box to “Yes” or “No”. Press the
keypad to return to Global Setup Menu. If no changes
were made, press the or keypad to return
to Global Setup Menu.
PHM1045R
Figure 48
Rapid Advance
Enable the Rapid Advance
Feature During Cycle Operation?
NoYe s
PHM1046R
Figure 49
Shakeout Menu
Shake Out Time
Sec40